Description: Fusing motor malfunction
• The fusing motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the fusing motor is being rotated.
Remedy: 1 Check the M4 connector for proper connection and correct as necessary. 2 Check the fuser unit driving mechanism for possible overload and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M4 operation check MFPB PJ19MFPB-3 to 9 J-3. 5 Change M4. 6 Change MFPB.
Description: 2nd image transfer pressure / retraction failure
• The 2nd image transfer retraction position sensor is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started. • The 2nd image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS10 sensor check MFPB PJ16MFPB-8 (ON) C-4 7 CL5 operation check MFPB PJ10MFPB-5 (ON) C-6 8 M3 operation check MFPB PJ11MFPB-1 to 7 J-3 9 Change M3. 10 Change CL5. 11 Change MFPB.
Description: 1st image transfer pressure / retraction failure
• The 1st image transfer retraction position sensor is not activated (retracted position) within a given period of time after the intermediate transport motor has started rotating. • The 1st image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the intermediate transport motor has started rotating.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS9 sensor check MFPB PJ7MFPB-11 (ON) J-5. 7 CL4 operation check MFPB PJ19MFPB-2 (REM) J-3 to 4. 8 M3 operation check MFPB PJ11MFPB-1 to 7 J-3. 9 Change M3. 10 Change CL4. 11 Change MFPB.
Description: Polygon motor malfunction
• The polygon motor does not rotate evenly even after the lapse of a given period of time after it has been started. • The motor lock signal remains HIGH for a given period of consecutive time while the polygon motor is being rotated.
Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change MFPB.
Description: Heating roller warm-up failure
• The thermistor /1 does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started.
Remedy: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change MFPB. 5 Change DCPU.
Description: Thermistor open-circuit failure
• The temperature detected by the thermistor does not reach a predetermined level even after the lapse of a given period time after the warm-up cycle has been started.
Remedy: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change MFPB. 5 Change DCPU.
Description: Thermistor resistance failure
• The difference between the temperature detected by thermistor/1 and that detected by thermistor/2 exceeds a predetermined value.
Remedy: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change MFPB. 5 Change DCPU.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.