Các lỗi thường gặp

Code :
  • Code: C060
  • Description: Firmware update error
    • Firmware update fails to complete correctly during update.
  • Remedy: 1 Reboot the main body. 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary. 3 Check the firmware update file and if the file is not the correct one, update the firmware again. 4 Check the firmware update procedure and if the procedure is not correct, update the firmware again. 5 Update the firmware again. 6 Check the MFPB/2 connector for proper connection and correct as necessary. 7 Change MFPB/2.
  • Code: CF01
  • Description: BB error
    • Contact the responsible people of KONICA MINOLTA before taking some countermeasures.
  • Remedy:
  • Code: FFFF
  • Description: Interface communication error
    • Correct communication is failed when receiving/sending the command between PRCB and MFPB/2.
  • Remedy: 1 Reboot the main body. 2 Check the MFPB/2 connector for proper connection and correct as necessary 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change PRCB. 5 Change MFPB/2.