Các lỗi thường gặp

Code :
  • Code: 004E
  • Description: DC power supply fan motor malfunction
    • The DC power supply fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the DC power supply fan motor is being rotated.
  • Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check PRCB PJ34-3 (LOCK) C to D-14. 4 Change FM1. 5 Change PRCB.
  • Code: 0060
  • Description: Fusing motor malfunction
    • The fusing motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the fusing motor is being rotated.
  • Remedy: 1 Check the M4 connector for proper connection and correct as necessary. 2 Check the fuser unit driving mechanism for possible overload and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M4 operation check PRCB PJ19-3 to 9 L-4. 5 Change M4. 6 Change PRCB.
  • Code: 0094
  • Description: 2nd image transfer pressure / retraction failure
    • The 2nd image transfer retraction position sensor is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started. • The 2nd image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started.
  • Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the PRCB connector for proper connection and correct as necessary. 6 PS10 sensor check PRCB PJ16-8 (ON) C to D-5. 7 CL5 operation check PRCB PJ10-5 (REM) C to D-7 to 8. 8 M3 operation check PRCB PJ11-1 to 7 L-4. 9 Change M3. 10 Change CL5. 11 Change PRCB.
  • Code: 0096
  • Description: 1st image transfer pressure / retraction failure
    • The 1st image transfer retraction position sensor is not activated (retracted position) within a given period of time after the intermediate transport motor has started rotating. • The 1st image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the intermediate transport motor has started rotating.
  • Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the PRCB connector for proper connection and correct as necessary. 6 PS9 sensor check PRCB PJ7-11 (ON) L-6. 7 CL4 operation check PRCB PJ19-2 (REM) L-4 to 5. 8 M3 operation check PRCB PJ11-1 to 7 L-4. 9 Change M3. 10 Change CL4. 11 Change PRCB.
  • Code: 0300
  • Description: Polygon motor malfunction
    • The polygon motor does not rotate evenly even after the lapse of a given period of time after it has been started. • The motor lock signal remains HIGH for a given period of consecutive time while the polygon motor is being rotated.
  • Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PRCB.
  • Code: 0310
  • Description: Laser malfunction
    • The SOS signal is not detected within a given period of time after the output of the laser has been started.
  • Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PRCB.
  • Code: 0500
  • Description: Heating roller warm-up failure
    • The thermistor /1 does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started.
  • Remedy: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and PRCB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change PRCB. 5 Change DCPU.
  • Code: 0502
  • Description: Thermistor open-circuit failure
    • The temperature detected by the thermistor does not reach a predetermined level even after the lapse of a given period time after the warm-up cycle has been started.
  • Remedy: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and PRCB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change PRCB. 5 Change DCPU.