Description: HDD access error
• When correct access to the hard disk kit is failed during access.
Remedy: 1 Reboot the main body. 2 Check the HDD connector for proper connection and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 Change HDD. 5 Change MFPB.
Description: HDD full error
• Range for user space is full during access to the hard disk kit.
Remedy: 1 Reboot the main body. 2 Delete the job hold in [PROOF/PRINT MENU] to increase the available range for user space. 3 Check the HDD connector for proper connection and correct as necessary. 4 Format HDD with [SYS DEFAULT MENU]- [HDD FORMAT.] 5 Change HDD.
Description: Compact flash access error
• When correct access to the compact flash card is failed during access.
Remedy: 1 Reboot the main body. 2 Check the compact flash for proper connection and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 Change compact flash. 5 Change MFPB.
Description: Compact flash full error
• Range for user space is full during access to the compact flash card.
Remedy: 1 Reboot the main body. 2 Delete the job hold in [PROOF/PRINT MENU] to increase the available range for user space. 3 Check the compact flash for proper connection and correct as necessary. 4 Format compact flash with [SYS DEFAULT MENU]-[CARD FORMAT.] 5 Change compact flash.
Description: Firmware update error
• Firmware update fails to complete correctly during update.
Remedy: 1 Reboot the main body. 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary. 3 Check the firmware update file and if the file is not the correct one, update the firmware again. 4 Check the firmware update procedure and if the procedure is not correct, update the firmware again. 5 Update the firmware again. 6 Check the MFPB connector for proper connection and correct as necessary. 7 Change MFPB.
Description: Interface Communication error
• Correct communication is failed when receiving/ sending the command between MFPB and PRCB.
Remedy: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary 3 Check the MFPB connector for proper connection and correct as necessary. 4 Change MFPB. 5 Change PRCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.