Code: C050

Display: HDD ERROR
Description: HDD access error
• When correct access to the hard disk kit is failed during access.
Remedy: 1 Reboot the main body. 2 Check the HDD connector for proper connection and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 Change HDD. 5 Change MFPB.

Code: C051

Display: HDD DISK FULL
Description: HDD full error
• Range for user space is full during access to the hard disk kit.
Remedy: 1 Reboot the main body. 2 Delete the job hold in [PROOF/PRINT MENU] to increase the available range for user space. 3 Check the HDD connector for proper connection and correct as necessary. 4 Format HDD with [SYS DEFAULT MENU]- [HDD FORMAT.] 5 Change HDD.

Code: C052

Display: CARD ERROR
Description: Compact flash access error
• When correct access to the compact flash card is failed during access.
Remedy: 1 Reboot the main body. 2 Check the compact flash for proper connection and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 Change compact flash. 5 Change MFPB.

Code: C053

Display: CARD FULL
Description: Compact flash full error
• Range for user space is full during access to the compact flash card.
Remedy: 1 Reboot the main body. 2 Delete the job hold in [PROOF/PRINT MENU] to increase the available range for user space. 3 Check the compact flash for proper connection and correct as necessary. 4 Format compact flash with [SYS DEFAULT MENU]-[CARD FORMAT.] 5 Change compact flash.

Code: C060

Display: UPDATE ERROR
Description: Firmware update error
• Firmware update fails to complete correctly during update.
Remedy: 1 Reboot the main body. 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary. 3 Check the firmware update file and if the file is not the correct one, update the firmware again. 4 Check the firmware update procedure and if the procedure is not correct, update the firmware again. 5 Update the firmware again. 6 Check the MFPB connector for proper connection and correct as necessary. 7 Change MFPB.

Code: FFFF

Display: I/F COMM ERROR
Description: Interface Communication error
• Correct communication is failed when receiving/ sending the command between MFPB and PRCB.
Remedy: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary 3 Check the MFPB connector for proper connection and correct as necessary. 4 Change MFPB. 5 Change PRCB.