Description: ROM contents error upon startup (PRT)
• A fault is detected in a sequence of ROM contents check of the mechanical control board (MFPB) during starting.
Remedy: 1 Check the ROM version. 2 Rewrite the firmware. 3 Replace the appropriate board.
Description: ROM contents error (PRT)
• The wrong model of firmware is detected in the engine during the initial connection to the engine is being checked.
Remedy: 1 Rewrite the firmware. 2 Change PRCB 2.1. Turn OFF the power switch and replace the current PRCB with a new one. (When using a PRCB of another machine in service, be sure to use a PRCB installed in the same model.) 2.2. Update the PRCB firmware. 2.3. After completing the firmware update, turn OFF and ON the power switch and check to see that warm-up is started. 2.4. When the trouble cannot be solved, reinstall the removed PRCB to the original board. NOTE • When taking the above steps, check whether PRCB is defective or not without replacing the SV ERB. 3 Change SV ERB 3.1. Replace the current SV ERB with a new one. 3.2. Turn ON the power switch and check to see that warm-up is started. (One minute is spent to prepare the new SV ERB for use. During the period, the control panel backlight stays off.) 3.3. Make the specified readjustments. 4 If the above actions do not solve the problem, contact KMBT.
Description: ROM contents error (MSC)
• The wrong model of firmware is detected in the MFP board when the power switch is turned ON.
Remedy: 1 Check the ROM version. 2 Rewrite the firmware. 3 Replace the corresponding board. 4 When not reviving even if the above-mentioned procedure is done, contact the responsible people of KMBT.