Các lỗi thường gặp

Code :
  • Code: C0001
  • Description: LCT connection failed
  • Remedy:
  • Code: C0202
  • Description: Tray 2 feeder up/down abnormality
    • The paper feed tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
  • Remedy: 1 Check the M8 connector for proper connection and correct as necessary. 2 Check the connector of M8 for proper drive coupling and correct as necessary. 3 PS8 I/O check PRCB CN12PRCB-3 (ON) D-8. 4 M8 operation check PRCB CN11PRCB-4 (REM) D-13. 5 Change M8. 6 Change PRCB.
  • Code: C0204
  • Description: Tray 3 feeder up/down abnormality
    • The paper feed tray 3 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
  • Remedy: 1 Check the M9 connector for proper connection and correct as necessary. 2 Check the connector of M9 for proper drive coupling and correct as necessary. 3 PS15 I/O check PRCB CN9PRCB-3 (ON) D-9. 4 M9 operation check PRCB CN7PRCB-9 (REM) D-11. 5 Change M9. 6 Change PRCB.
  • Code: C0206
  • Description: Tray 4 feeder up/down abnormality
  • Remedy:
  • Code: C0208
  • Description: Tray 5 feeder up/down abnormality
  • Remedy:
  • Code: C0209
  • Description: LCT elevator motor malfunction
  • Remedy:
  • Code: C0210
  • Description: LCT ascent motion failure
  • Remedy:
  • Code: C0211
  • Description: Tray 1 feeder up/down abnormality
    • The paper feed tray 1 lift-up position sensor is not unblocked even when the transport motor has turned for a given number of pulses after the sequence to move the paper lifting plate from the standby position to the feed position was started. • The paper feed tray 1 lift-up position sensor is not blocked even when the transport motor has turned for a given number of pulses after the sequence to move the paper lifting plate from the feed position to the standby position was started.
  • Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as necessary. 3 PS17 I/O check PRCB CN6PRCB-7 (ON) D-2. 4 SL1 operation check PRCB CN6PRCB-4 (ON) D-1. 5 M1 operation check PRCB CN34PRCB-10 (REM) PRCB CN34PRCB-13 (LOCK) D-22. 6 Change SL1. 7 Change M1. 8 Change PRCB.