Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta Magicolor 8650 — Trang 12/14

Code: C4154

Description: Polygon motor rotation trouble (K)
Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PHREYB. 4 Change PRCB.

Code: C4551

Description: Laser malfunction (C)
• SOS signal is not detected even after the lapse of a given period of time after staring the laser output. • SOS signal is not detected for a given period of time during printing or image stabilization adjustment.
Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PHREYB. 4 Change PRCB.

Code: C4552

Description: Laser malfunction (M)
Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PHREYB. 4 Change PRCB.

Code: C4553

Description: Laser malfunction (Y)
Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PHREYB. 4 Change PRCB.

Code: C4554

Description: Laser malfunction (K)
Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PHREYB. 4 Change PRCB.

Code: C5102

Description: Transport motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M1 operation check PRCB CN34PRCB-10 (REM) PRCB CN34PRCB-13 (LOCK) D-22. 5 Change M1. 6 Change PRCB.

Code: C5103

Description: Transport motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M1 operation check PRCB CN34PRCB-10 (REM) PRCB CN34PRCB-13 (LOCK) D-22. 5 Change M1. 6 Change PRCB.

Code: C5351

Description: Power supply cooling fan motor/1’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the FM5 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM5 operation check PRCB CN30PRCB-11 (ON) PRCB CN30PRCB-12 (LOCK) K-8. 4 Change FM5. 5 Change DCPU. 6 Change PRCB.