Description: Abnormally low fuser unit thermistor temperature • The fuser temperature remains below 120 °C/248 °F for 10 s. • When power is turned on, the fuser temperature does not reach 40 °C/ 104 °F even if 14 (FS-9100DN) or 20 (9500DN) seconds elapse.
Causes: Poor contact in the fuser unit thermistor connector terminals. Broken fuser unit thermistor wire. Fuser unit thermistor installed incorrectly. Fuser unit thermostat triggered. Fuser unit heater M or S installed incorrectly. Broken fuser unit heater M or S wire.
Remedy: Check the connection of connector CN10 on the engine controller PWB and the continuity across the connector terminals. Repair or replace if necessary. Measure the resistance. If it is ∞, replace the fuser unit thermistor (see page 1-6-22). Check and reinstall if necessary. Check for continuity. If none, replace the fuser unit thermostat (see page 1-6-22). Check and reinstall if necessary. Check for continuity. If none, replace the fuser unit heater M or S (see page 1-6-20).
Description: Fuser unit connector insertion problem • Absence of the fuser unit is detected continuously for 1500 ms while there is no error on the printer.
Causes: Fuser unit connector inserted incorrectly. Defective fuser unit connector.
Remedy: Reinsert the fuser unit connector if necessary. Replace the fuser unit.
Description: Broken fuser unit thermistor wire • The fuser temperature remains at 0 °C/32 °F for 30 s continuously when the fuser heater is on. co
Causes: Poor contact in the fuser unit thermistor connector terminals. Broken fuser unit thermistor wire.
Remedy: Check the connection of connector CN10 on the engine controller PWB and the continuity across the connector terminals. Repair or replace if necessary. Measure the resistance. If it is ∞, replace the fuser unit thermistor.
Description: Image formation unit connector insertion problem • Absence of the image formation unit is detected continuously for 1500 ms while there is no error on the printer.
Causes: Image formation unit connector inserted incorrectly. Defective image formation unit connector.
Remedy: Reinsert the image formation unit connector if necessary. Replace the image formation unit.
Description: Drum unit connector insertion problem • Absence of the drum unit is detected continuously for 1500 ms while there is no error on the printer.
Causes: Drum unit connector inserted incorrectly. Defective drum unit connector.
Remedy: Reinsert the drum unit connector if necessary. Replace the drum unit.
Description: Broken external temperature thermistor wire • The input voltage is above 4.5 V.n unit
Causes: Poor contact in the humidity sensor board connector terminals. Defective external temperature thermistor.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the humidity sensor board.
Description: Short-circuited external temperature thermistor • The input voltage is below 0.5 V.
Causes: Poor contact in the humidity sensor board connector terminals. Defective external temperature thermistor.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the humidity sensor board.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.