Description: Fuser thermistor 1 break error During warming up, fuser thermistor 1 does not detect temperature rise of 1C/ 1.8F for 10 s. When the difference of temperature of fuser thermistor 1 and 2 becomes 90aC/ 195F or more is detected continuously for 6 s.
Remedy: Defective fuser heater 1. Check for continuity across each heater. If none, replace the fuser unit. Installation defectiveness on fuser thermistor 1. Measure the resistance. If it is ∞Ω, replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
Code: C6040
Description: Fuser heater error Fuser thermistor 1 detects temperature change of 20C/36F or more for 160 ms 100 times or more since the power is turned on.
Remedy: Defective fuser heater 1. Check for continuity across each heater. If none, replace the fuser unit. Installation defectiveness on fuser thermistor 1. Measure the resistance. If it is ∞Ω, replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
Code: C6050
Description: Abnormally low fuser thermistor 1 temperature During printing, the temperature at the heat roller lower than 110C/230F is detected continuously for 6 s.
Causes: Defective fuser heater 1. Defective PWB.
Remedy: Defective fuser heater 1. Replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
Code: C6100
Description: Fuser heater 2 break Fuser thermistor 2 detected less than 100C/212F for 120 s during driving. Fuser thermistor 2 deduced less than 150C/302F for 300 s during driving. Fuser thermistor 2 deduced less than 100C/212F for 5 s during driving.
Remedy: Defective fuser heater 2. Check for continuity across each heater. If none, replace the fuser unit. Defective fuser thermostat 2. Check for continuity across thermostat. If none, remove the cause and replace the fuser unit. Installation defectiveness on fuser thermistor 2. Measure the resistance. If it is ∞Ω, replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
Code: C6120
Description: Abnormally high fuser thermistor 2 temperature The fuser temperature exceeds 190C/ 374F for 1 s.
Causes: Installation defectiveness on fuser thermistor 2. Defective PWB.
Remedy: Installation defectiveness on fuser thermistor 2. Measure the resistance. If it is ∞Ω, replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
Code: C6130
Description: Fuser thermistor 2 break error Fuser thermistor 2 detects a temperature of 30C/86F or lower for 75 s.
Remedy: Installation defectiveness on fuser thermistor 2. Measure the resistance. If it is ∞Ω, replace the fuser unit. Defective fuser heater 2. Check for continuity across each heater. If none, replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
Code: C6150
Description: Abnormally low fuser thermistor 2 temperature
Causes: Defective fuser heater 2. Defective PWB.
Remedy: Defective fuser heater 2. Replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
Code: C6200
Description: Fuser heater 1 edge break During warming up, fuser thermistor 1 does not detect temperature rise of 1C/ 1.8F for 10 s. Fuser thermistor 1 does not reach 90C/ 194F even after 30 s during warming up.
Remedy: Defective fuser heater 1. Check for continuity across each heater. If none, replace the fuser unit. Defective fuser thermostat 1. Check for continuity across thermostat. If none, remove the cause and replace the fuser unit. Installation defectiveness on fuser thermistor 1. Measure the resistance. If it is ∞Ω, replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.