Description: Image processing problem JAM05 is detected twice.
Causes: Defective main PWB. Defective main PWB. The battery is disconnected from the main PWB.
Remedy: Defective main PWB. Replace the main PWB and check for correct operation.
Code: C0840
Description: Faults of RTC The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
Causes: Defective main PWB. The battery is disconnected from the main PWB.
Remedy: Defective main PWB. Replace the main PWB and check for correct operation. The battery is disconnected from the main PWB. Check visually and remedy if necessary.
Code: C1010
Description: Lift motor 1 error After cassette 1 is inserted, lift switch 1 does not turn on within 12 s. This error is detected four times successively.
Causes: Poor contact in the connector terminals. Broken gears or couplings of lift motor 1. Defective lift motor 1. Defective lift switch 1. Poor contact in the connector terminals. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector of lift motor 1 and the connector YC3 on the feed PWB, and the continuity across the connector terminals. Repair or replace if necessary. Broken gears or couplings of lift motor 1. Replace lift motor 1. Defective lift motor 1. Check for continuity across the coil. If none, replace lift motor 1. Defective lift switch 1. Check if YC4-2 on the feed PWB goes low when lift switch 1 is turned off. If not, replace lift switch 1. Poor contact in the connector terminals. Check the connection of connector of lift switch 1 and the connector YC4 on the feed PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the feed PWB or engine PWB and check for correct operation.
Code: C1020
Description: Lift motor 2 error After cassette 2 is inserted, lift switch 2 does not turn on within 12 s. This error is detected four times successively.
Causes: Poor contact in the connector terminals. Broken gears or couplings of lift motor 2. Defective lift motor 2. Defective lift switch 2. Poor contact in the connector terminals. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector of lift motor 2 and the connector YC3 on the feed PWB, and the continuity across the connector terminals. Repair or replace if necessary. Broken gears or couplings of lift motor 2. Replace lift motor 2. Defective lift motor 2. Check for continuity across the coil. If none, replace lift motor 2. Defective lift switch 2. Check if YC4-8 on the feed PWB goes low when lift switch 2 is turned off. If not, replace lift switch 2. Poor contact in the connector terminals. Check the connection of connector of lift switch 2 and the connector YC4 on the feed PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the feed PWB or engine PWB and check for correct operation.
Code: C1030
Description: PF lift motor 1 error (optional paper feeder) After cassette 3 is inserted, PF lift switch 1 does not turn on within 12 s. This error is detected two times successively. During driving the motor, the lift overcurrent protective monitor signal is detected for 500 ms or more two times successively. However, the first 1 s after PF lift motor 1 is turned on is excluded from detection.
Causes: Poor contact in the connector terminals. Broken gears or couplings of PF lift motor 1. Defective PF lift motor 1. Defective PF lift switch 1.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC27 on the engine PWB and the connector on the PF main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Broken gears or couplings of PF lift motor 1. Replace PF lift motor 1. Defective PF lift motor 1. Check for continuity across the coil. If none, replace PF lift motor 1. Defective PF lift switch 1. Check if YC1-7 on the PF main PWB goes low when PF lift switch 1 is turned off. If not, replace PF lift switch 1.
Code: C1040
Description: PF lift motor 2 error (optional paper feeder) After cassette 4 is inserted, PF lift switch 2 does not turn on within 12 s. This error is detected two times successively. During driving the motor, the lift overcurrent protective monitor signal is detected for 500 ms or more two times successively. However, the first 1 s after PF lift motor 2 is turned on is excluded from detection.
Causes: Poor contact in the connector terminals. Broken gears or couplings of PF lift motor 2. Defective PF lift motor 2. Defective PF lift switch 2.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC27 on the engine PWB and the connector on the PF main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Broken gears or couplings of PF lift motor 2. Replace PF lift motor 2. Defective PF lift motor 2. Check for continuity across the coil. If none, replace PF lift motor 2. Defective PF lift switch 2. Check if YC1-9 on the PF main PWB goes low when PF lift switch 2 is turned off. If not, replace PF lift switch 2.
Code: C1100
Description: PF lift motor 1 error (optional 3000- sheet paper feeder) A motor over-current signal is detected continuously for 1 s or longer.
Causes: Poor contact in the connector terminals. PF lift motor 1 does not rotate correctly (the motor is overloaded).
Remedy: Poor contact in the connector terminals. Check the connection of connector YC27 on the engine PWB and the connector on the PF main PWB, and the continuity across the connector terminals. Repair or replace if necessary. PF lift motor 1 does not rotate correctly (the motor is overloaded). Check the gears and remedy if necessary.
Code: C1110
Description: PF lift motor 2 error (optional 3000- sheet paper feeder) A motor over-current signal is detected continuously for 1 s or longer.
Causes: Poor contact in the connector terminals. PF lift motor 2 does not rotate correctly (the motor is overloaded).
Remedy: Poor contact in the connector terminals. Check the connection of connector YC27 on the engine PWB and the connector on the PF main PWB, and the continuity across the connector terminals. Repair or replace if necessary. PF lift motor 2 does not rotate correctly (the motor is overloaded). Check the gears and remedy if necessary.