Description: Abnormally low toner density detected by Cyan ATDC Sensor
Toner density that is 2 % or more lower than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence.
Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 ATDC Sensor spring moving part operates properly. NO: Correct. 3 Hopper supplies toner properly. NO: Correct. 4 ATDC Sensor LED is dirty. YES: Clean. 5 ATDC Sensor LED emits light properly. NO: Check connector for connection. Check harness. 6 Imaging Unit Shutter operates properly. NO: Correct. 7 The problem has been eliminated through the checks of steps up to 6. NO: Change Master Board.
Description: Abnormally high toner density detected by Cyan ATDC Sensor
Toner density that is 4 % or more higher than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence.
Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Bias voltage is properly applied to the ATDC Sensor window. NO: Check wiring. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Master Board.
Description: Abnormally low toner density detected by Magenta ATDC Sensor
Toner density that is 2 % or more lower than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence.
Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 ATDC Sensor spring moving part operates properly. NO: Correct. 3 Hopper supplies toner properly. NO: Correct. 4 ATDC Sensor LED is dirty. YES: Clean. 5 ATDC Sensor LED emits light properly. NO: Check connector for connection. Check harness. 6 Imaging Unit Shutter operates properly. NO: Correct. 7 The problem has been eliminated through the checks of steps up to 6. NO: Change Master Board.
Description: Abnormally high toner density detected by Magenta ATDC Sensor
Toner density that is 4 % or more higher than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence.
Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Bias voltage is properly applied to the ATDC Sensor window. NO: Check wiring. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Master Board.
Description: Abnormally low toner density detected by Yellow ATDC Sensor
Toner density that is 2 % or more lower than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence.
Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 ATDC Sensor spring moving part operates properly. NO: Correct. 3 Hopper supplies toner properly. NO: Correct. 4 ATDC Sensor LED is dirty. YES: Clean. 5 ATDC Sensor LED emits light properly. NO: Check connector for connection. Check harness. 6 Imaging Unit Shutter operates properly. NO: Correct. 7 The problem has been eliminated through the checks of steps up to 6. NO: Change Master Board.
Description: Abnormally high toner density detected by Yellow ATDC Sensor
Toner density that is 4 % or more higher than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence.
Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Bias voltage is properly applied to the ATDC Sensor window. NO: Check wiring. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Master Board.
Description: Abnormally low toner density detected by Black ATDC Sensor
Toner density that is 2 % or more lower than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence.
Remedy: 1 Image density is low. YES: Check and correct Imaging Unit Bk Shutter. 2 The problem has been eliminated through the check of step 1. NO: Check and correct Hopper. 3 The problem has been eliminated through the check of step 2. NO: Change Master Board.
Description: Abnormally high toner density detected by Black ATDC Sensor
Toner density that is 4 % or more higher than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence.
Remedy: 1 Imaging Unit Bk is installed correctly. NO: Reinstall. 2 Each of Imaging Unit Bk contacts makes good contact. NO: Clean or correct. 3 ATDC Sensor harness is open-circuited. YES: Change Imaging Unit Bk.Chan
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.