Description: Imaging Unit Motor Bk’s failuretoturn
The Lock signal remains faulty for a continuous 1sec. period after the motor rotation has stabilized and before the motor starts decelerating.
Remedy: 1 Imaging Unit Motor turns when the Start key is pressed. NO: Correct drive coupling (drive transmitting gear engagement, coupling engagement). Check that the LED Assy is locked in position. 2 Imaging Unit Motor rotation when the Start key is pressed: Cyan: the voltage across PJ12I-3B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Magenta: the voltage across PJ12I-7A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Yellow: the voltage across PJ12I-3A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Black: the voltage across PJ12I-7B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board.
Description: Imaging Unit Motor Bk turning at abnormal timing
The Lock signal remains faulty for a continuous 1sec. period after the motor has completely stopped and before the motor starts accelerating.
Remedy: 1 Imaging Unit Motor rotation while it is being energized: Cyan: the voltage across PJ12I-3B on Master Board and GND remains DC 0 V. Magenta: the voltage across PJ12I-7A on Master Board and GND remains DC 0 V. Yellow: the voltage across PJ12I-3A on Master Board and GND remains DC 0 V. Black: the voltage across PJ12I-7B on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
Description: Fusing Cooling Fan Motor 2’s failure to turn
A Fusing Cooling Fan Lock signal is detected for a continuous 3-sec. period while Fusing Cooling Fan Motor 2 is turning.
Remedy: 1 Fusing Cooling Fan Motor 1 turns when the Start key is pressed. NO Check connector for connection. Check fan for overload. 2 Fusing Cooling Fan Motor 1 rotation when the Start key is pressed: the voltage across PJ14I-13A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change Master Board. NO: Change motor.
Description: Fusing Cooling Fan Motor 1’s failure to turn
A Fusing Cooling Fan Lock signal is detected for a continuous 3-sec. period while the Fusing Cooling Fan Motor is turning.
Remedy: 1 Fusing Cooling Fan Motor 2 turns when the Start key is pressed. NO Check connector for connection. Check fan for overload. 2 Fusing Cooling Fan Motor 2 rotation when the Start key is pressed: the voltage across PJ14I-3A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board.
Description: Ozone Ventilation Fan Motor’s failure to turn
An Ozone Fan Lock signal is detected for a continuous 3-sec. period while the Ozone Ventilation Fan Motor is turning.
Remedy: 1 Ozone Ventilation Fan Motor turns when the Start key is pressed. NO: Check connector for connection. Check fan for overload. 2 Ozone Ventilation Fan Motor rotation when the Start key is pressed: the voltage across PJ10I-15 on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. NO: Change Master Board. 3 Ozone Ventilation Fan Motor rotation when the Start key is pressed: the voltage across CN2HV3-3 on High Voltage Unit 3 and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change High Voltage Unit 3.
Description: Power Supply Cooling Fan Motor’s failure to turn
A Power Supply Cooling Fan Lock signal is detected for a continuous 3-sec. period while the Power Supply Cooling Fan Motor is turning.
Remedy: 1 Power Supply Cooling Fan Motor turns when the Start key is pressed. NO: Check connector for connection. Check fan for overload. 2 Power Supply Cooling Fan Motor rotation when the Start key is pressed: the voltage across PJ13PU1-3 on DC Power Supply 1 and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change DC Power Supply 1.
Description: Fusing Drive Motor’s failure to turn
A Fusing Drive Motor Lock signal remains faulty for a predetermined continuous period of time while the Fusing Drive Motor is turning.
Remedy: 1 Fusing Drive Motor turns when the Start key is pressed. NO: Check connector for connection. Correct drive coupling (drive transmitting gear engagement). 2 Fusing Drive Motor rotation when the Start key is pressed: the voltage across PJ13I-1A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board. 3 Fusing Drive Motor rotation when the Start key is pressed: the voltage across PJ7PU1- 4 on DC Power Supply 1 and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. NO Change DC Power Supply 1.
Description: Fusing Drive Motor turning at abnormal timing
The Fusing Drive Motor Lock signal remains faulty for a predetermined continuous period of time while the Fusing Drive Motor remains stationary.
Remedy: 1 Fusing Drive Motor rotation while it is being energized: the voltage across PJ13I-1A on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.