Các lỗi thường gặp

Code :
  • Code: 2212
  • Description: Drum motor YCM startup error
    Drum motor YCM is not stabilized within 3 s since the motor is activated.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system. Defective motor. Defective PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum motor YCM and engine PWB (YC3)
    Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
    Defective motor. Replace the Drum motor YCM.
    Defective PWB. Replace the engine PWB and check for correct operation.
  • Code: 2300
  • Description: Fuser motor steady-state error
    The rated speed signal detected the stability OFF continuously for 1 s after the fuser motor stabilizes.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system. Defective motor. Defective PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser motor and engine PWB (YC4)
    Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
    Defective motor. Replace the Fuser motor.
    Defective PWB. Replace the engine PWB and check for correct operation.
  • Code: 2310
  • Description: Fuser motor startup error
    Fuser motor is not stabilized within 3 s since the motor is activated.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system. Defective motor. Defective PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser motor and engine PWB (YC4)
    Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
    Defective motor. Replace the fuser motor.
    Defective PWB. Replace the engine PWB and check for correct operation.
  • Code: 2500
  • Description: Conveying motor 2 steadystate error
    The rated speed signal detected the stability OFF continuously for 1 s after the conveying motor 2 stabilizes.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system. Defective motor. Defective PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Conveying motor 2 and video PWB (YC5)
    Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
    Defective motor. Replace the Conveying motor 2.
    Defective PWB. Replace the video PWB and check for correct operation.
  • Code: 2510
  • Description: Conveying motor 2 startup error
    Conveying motor 2 is not stabilized within 2 s since the motor is activated.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system. Defective motor. Defective PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Conveying motor 2 and engine PWB (YC2)
    Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
    Defective motor. Replace the conveying motor 2.
    Defective PWB. Replace the engine PWB and check for correct operation.
  • Code: 2550
  • Description: Conveying motor 1 steadystate error
    The rated speed signal detected the stability OFF continuously for 1 s after the conveying motor 1 stabilizes.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system. Defective motor. Defective PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Conveying motor 1 and engine PWB (YC2)
    Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
    Defective motor. Replace the Conveying motor 1.
    Defective PWB. Replace the engine PWB and check for correct operation.
  • Code: 2560
  • Description: Conveying motor 1 startup error
    Conveying motor 1 is not stabilized within 2 s since the motor is activated.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system. Defective motor. Defective PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Conveying motor 1 and engine PWB (YC2)
    Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
    Defective motor. Replace the conveying motor 1.
    Defective PWB. Replace the engine PWB and check for correct operation.
  • Code: 2600
  • Description: PF drive motor error (paper feeder)
    When the PF drive motor is driven, error signal is detected continuously for 1 s.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system. Defective motor. Defective PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor and PF main PWB (YC2)
    Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective motor. Replace the PF drive motor.
    Defective PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).