Description: Sensor error in coin vender change (Yen 10) Change is empty despite change is enough.
Causes: Coin jam in the change tube. Poor contact in the connector. Defective change empty sensor. Defective coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Poor contact in the connector. Check if the change empty sensor is intact. Defective coin vender control PWB. Defective change empty sensor. Replace the coin mec.
Description: Sensor error in coin vender change (Yen 50) Change is empty despite change is enough.
Causes: Coin jam in the change tube. Poor contact in the connector. Defective change empty sensor. Defective coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Poor contact in the connector. Check if the change empty sensor is intact. Defective coin vender control PWB. Defective change empty sensor. Replace the coin mec.
Description: Sensor error in coin vender change (Yen 100) Change is empty despite change is enough.
Causes: Coin jam in the change tube. Poor contact in the connector. Defective change empty sensor. Defective coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Poor contact in the connector. Check if the change empty sensor is intact. Defective coin vender control PWB. Defective change empty sensor. Replace the coin mec.
Description: Sensor error in coin vender change (Yen 500) Change is empty despite change is enough.
Causes: Coin jam in the change tube. Poor contact in the connector. Defective change empty sensor. Defective coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Poor contact in the connector. Check if the change empty sensor is intact. Defective change empty sensor. Defective coin vender control PWB. Replace the coin mec.
Remedy: 1. Reinsert the connector if its connection is loose. Main PWB (YC25) and ISC PWB (YC4) 2. Replace the main PWB. 3. Replace the ISC PWB 4. Contact the Service Support.
Remedy: 1. Reinsert the connector if its connection is loose. DP relay PWB (YC2) and DP SHD PWB (YC3) 2. Replace the main PWB. 3. Replace the DP SHD PWB. 4. Contact the Service Support.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.