Description: Broken internal thermistor 2 wire An abnormal value is detected in the input data to inner temperature sensor 2.
Causes: Poor contact in the connector terminals. Defective engine PWB
Remedy: Poor contact in the connector terminals. Check the connection of connector YC8 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective engine PWB. Replace the engine PWB and check for correct operation.
Code: C7250
Description: Short-circuited internal thermistor 2 An abnormal value is detected in the input data to inner temperature sensor 2.
Causes: Poor contact in the connector terminals. Defective engine PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC8 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective engine PWB. Replace the engine PWB and check for correct operation.
Code: C7401
Description: Developing unit K type mismatch problem Absence of the developing unit K is detected.
Causes: Developing unit connector inserted incorrectly. Different type of the developing unit is installed.
Remedy: Developing unit connector inserted incorrectly. Reinsert the developing unit connector if necessary. Different type of the developing unit is installed. Install the correct developing unit.
Code: C7402
Description: Developing unit C type mismatch problem Absence of the developing unit C is detected.
Causes: Developing unit connector inserted incorrectly. Different type of the developing unit is installed.
Remedy: Developing unit connector inserted incorrectly. Reinsert the developing unit connector if necessary. Different type of the developing unit is installed. Install the correct developing unit.
Code: C7403
Description: Developing unit M type mismatch problem Absence of the developing unit M is detected.
Causes: Developing unit connector inserted incorrectly. Different type of the developing unit is installed.
Remedy: Developing unit connector inserted incorrectly. Reinsert the developing unit connector if necessary. Different type of the developing unit is installed. Install the correct developing unit.
Code: C7404
Description: Developing unit Y type mismatch problem Absence of the developing unit Y is detected.
Causes: Developing unit connector inserted incorrectly. Different type of the developing unit is installed
Remedy: Developing unit connector inserted incorrectly. Reinsert the developing unit connector if necessary. Different type of the developing unit is installed. Install the correct developing unit.
Code: C7411
Description: Drum unit K type mismatch problem Absence of the drum unit K is detected.
Causes: Drum unit connector inserted incorrectly. Different type of the drum unit is installed.
Remedy: Drum unit connector inserted incorrectly. Reinsert the drum unit connector if necessary. Different type of the drum unit is installed. Install the correct drum unit.
Code: C7412
Description: Drum unit C type mismatch problem Absence of the drum unit C is detected.
Causes: Drum unit connector inserted incorrectly. Different type of the drum unit is installed.
Remedy: Drum unit connector inserted incorrectly. Reinsert the drum unit connector if necessary. Different type of the drum unit is installed. Install the correct drum unit.