Description: Drum M EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Poor contact in the connector terminals. Defective drum PWB M.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC7 on the sub front PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective drum PWB M. Replace the drum unit M.
Description: Drum Y EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Defective drum PWB Y.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC3 on the sub front PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective drum PWB Y. Replace the drum unit Y.
Description: Developing unit K EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Poor contact in the connector terminals. Defective developing PWB K.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC4 on the main front PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective developing PWB K. Replace the developing unit K.
Description: Developing unit C EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Poor contact in the connector terminals. Defective developing PWB C.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the sub front PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective developing PWB C. Replace the developing unit C.
Description: Developing unit M EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Poor contact in the connector terminals. Defective developing PWB M.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC8 on the sub front PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective developing PWB M. Replace the developing unit M.
Description: Developing unit Y EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Poor contact in the connector terminals. Defective developing PWB Y.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC4 on the sub front PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective developing PWB Y. Replace the developing unit Y.
Description: High voltage control PWB error A communication error from high voltage control PWB is detected 10 times in succession
Causes: Poor contact in the connector terminals. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC30 on the engine PWB and the connector on the high voltage control PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the high voltage control PWB or engine PWB and check for correct operation.
Description: Punch motor problem (optional 3000sheet document finisher) The error signal of the punch motor is detected for more than 500 ms while the punch motor is operating.
Causes: Poor contact in the connector terminals. Defective punch motor. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector on the punch PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective punch motor. Replace the punch motor. Defective PWB. Replace the punch PWB or finisher main PWB and check for correct operation.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.