Các lỗi thường gặp

Code :
  • Code: 106
  • Display: Service call 106: Error
  • Description: The engine control logic is abnormal
  • Remedy: Power supply OFF/ON Replace TB3 board
  • Code: 120
  • Display: Service call 120: ERROR
  • Description: PU unit FAN motor error
  • Remedy: Replace TB3 board
  • Code: 121
  • Display: Service call 121: Error
  • Description: High-voltage power supply I/F error
  • Remedy: Is the cable between main board ant the high-voltage power supply unit correctly connected? Isn't there defective contact point?
    Reconnect correctly. Check the defective contact point of high-voltage system. Replace the high voltage power supply.
  • Code: 122
  • Display: Service call 122:Error
  • Description: Low-voltage power supply fan error. Low-voltage power supply temperature error.
  • Remedy: Is fan in low-voltage power supply unit operating? Is fan connector connected properly?
    Check connections for connector of fan. Replace low-voltage power supply. Replace fan motor. Replace low-voltage power supply.
  • Code: 123
  • Display: Service call 123: Error
  • Description: Environmental humidity abnormal/ humidity sensor disconnection
  • Remedy: the high-voltage power supply unit correctly connected?
    Reconnect correctly. Replace the high-voltage power supply.
  • Code: 124
  • Display: Service call 124: Error
  • Description: Environmental temperature abnormality
  • Remedy: Power supply OFF/ON Replace control panel board (PRP)
  • Code: 126
  • Display: Service call 126: Error
  • Description: The dewy of the device is detected
  • Remedy: Dew condensation occurs easily after the device is carried in from outside. After leaving it at room temperature for 2 hours to half a day, turn on the power again. Does the error recur? Turn on the power again after leaving the device for hours. Replace the high-voltage power supply.
  • Code: 127
  • Display: Service call 127: Error
  • Description: Fixed cooling fan error
  • Remedy: Is the connector connection of the fan normal? Does the error recur?
    Reconnect normally Replace the fan motor