Code: 123

Display: Service call 123:Error
Description: Abnormal environment humidty / Not connected humidity sensor.
Remedy: Does error reoccur? Power OFF/ON Replace the operator panel board (PRP)

Code: 124

Display: Service call 124:Error
Description: Abnormal environment temperature.
Remedy: Does error reoccur? Power OFF/ON Replace the operator panel board (PRN)

Code: 126

Display: Service call 126:Error
Description: Condensation in the printer was detected.
Remedy: Condensation iss likely to occur in printers carried from the outside. Turn on the printer again after it is exposed to room temperature for two hours to half a day. Does the error reoccur?
Turn on the printer again after it is left alone. Replace the operator panel board (PRP)

Code: 127

Display: Service call 127:Error
Description: Error detected at the fuser unit cooling fan.
Remedy: Is fan connector connected properly? Does error reoccur?
Connect properly again. Replace fan motor Replace PU board (PRN)

Code: 131 ... 134

Display: Service call 131:Error ~ 134:Error
Description: LED head fault detected. (131 = Y, 132 = M, 133 = C, 134 = K)
Remedy: Is LED head properly set? Does error reoccur?
Set properly for LED head unit. Turn power ON again. Replace LED head unit

Code: 142

Display: Service call 142:Error
Description: Error detented at ID position of Up/ Down
Remedy: Is ID unit set properly? Does error reoccur?
Reset ID unit. Turn power ON again. Replace ID Up/Down sensor.

Code: 150 ... 153

Display: Service call 150:Error ~ 153:Error
Description: ID unit fuse cannot be disconnected. (150 = Y, 151 = M, 152 = C, 153 = K)
Remedy: Is ID unit setting proper? Does error reoccur? Is error recovered by replacing PRT board?
Reset ID unit. Turn power ON again. After check connections of cable between PRT board and PU board, replace PRT board. Replace PU board (PRN)

Code: 154

Display: Service call 154:Error
Description: Belt unit fuse cannot be disconnected.
Remedy: Is belt unit setting proper? Does error reoccur?
Reset belt unit. Turn power ON again. Check cable connections and, replace PU board(PRN)