Code :
Tất cả lỗi
- - - - - - - - - - 001 002, 006, 007 020 020 023 030 031 035 040 041 042 ... 044 051 051 070 072 073 074 104 105 106 121 122 123 124 126 127 131 ... 134 142 150 ... 153 154 155 160 ... 163 170 ... 171 172, 173 ... 177 174 175 176 181, 182 190 200, 202 203, 204, 210, 214 209 220 901, 902 903, 904 905 906 907 908 FOC, F0D, FFE, FFF
Code: 906
Display: Service call 906:Error
Description: A short circuit error of frame thermistor (defective improper) detected. Remedy: Does error reoccur? Turn power ON again. Replace the fuser unit.
Code: 907
Display: Service call 907:Error
Description: A high temperature error (over 150°C) of frame thermistor detected. Remedy: Does error reoccur? Turn power ON again. Replace the fuser unit.
Code: 908
Display: Service call 908:Error
Description: A low temperature error (below [environmental temperature minus 10]°C) of frame thermistor detected. Remedy: Does error reoccur? Turn power ON again. Replace the fuser unit.
Code: FOC, F0D, FFE, FFF
Display: Power off/on 203:Error 204:Error 207:Error 208:Error 210:Error ~ 214:Error F0C:Error F0D:Error(C5400 only) FFE:Error(C5400 only) FFF:Error
Description: An error was detected of the CU program. (203~214 is not occure in usual operating.) Remedy: Reinstall the CU board. Is the error message displayed again? After turn power OFF, check connections between CU board and PU board. Then turn power ON again.