Mã lỗi OKI C5200 — Trang 6/8
Code:
Tất cả lỗi (60)
-
-
-
-
-
-
-
-
-
-
001
002, 006, 007
020
020
023
030
031
035
040
041
042 ... 044
051
051
070
072
073
074
104
105
106
121
122
123
124
126
127
131 ... 134
142
150 ... 153
154
155
160 ... 163
170 ... 171
172, 173 ... 177
174
175
176
181, 182
190
200, 202
203, 204, 210, 214
209
220
901, 902
903, 904
905
906
907
908
FOC, F0D, FFE, FFF
Display: Service call 155:Error
Description: Fuser unit fuse cannot be disconnected.
Remedy: Is fuser unit set properly? Does error reoccur? After cleaning for fuser connector, reset. Turn power ON again. Check cable connections and replace PU board (PRN)
Display: Service call 160:Error ~ 163:Error
Description: Error detected by toner sensor. (160 = Y, 161 = M, 162 = C, 163 = K) It does not occure in factory default setting.
Remedy: Is toner cartridge setting? Is toner lock lever setting? Does error reoccur? Set toner cartridge. Turn a lock lever of toner to a fixed position. Replace toner sensor or assembly.
Display: Service call 170:Error 171:Error
Description: Short circuit in fuser thermistor or open detected.
Remedy: Does error reoccur? Turn power ON again. Replace fuser unit.
Display: Service call 172:Error 173:Error 177:Error
Description: Abnormal temperature detected by fuser thermistor (high-temp or low temp.)
Remedy: Does error reoccur? Turn power ON again. Replace fuser unit.
Display: Service call 174:Error
Description: Short circuit in back up roller thermistor detected (at high temperature).
Remedy: Does error reoccur? Turn power ON again. Replace fuser unit.
Display: Service call 175:Error
Description: Open of back up roller thermistor detected (at low temperature).
Remedy: Does error reoccur? Turn power ON again. Replace fuser unit.
Display: Service call 176:Error
Description: Abnormal (high) temperature of back up roller thermistor detected.
Remedy: Does error reoccur? Turn power ON again. Replace fuser unit.
Display: Service call 181:Error 182:Error
Description: Option unit I/F error. (181 = Duplex Unit, 182 = Option Tray)
Remedy: Does error reoccur? Turn power ON again. After checking connection parts of connector, replace option unit.