Code: 124

Display: Service call 124: Error
Description: Environment temperature is abnormal.
Remedy: Does this error recur? Yes Turn off the power of the printer and back on. Replace the control panel board.

Code: 126

Display: Service call 126: Error
Description: Dew condensation of the printer is detected.
Remedy: This error can easily occur when a printer is brought in to indoor from outdoor. Leave the printer for 2 hours or half day under room temperature, and turn on the power again. Does this error recur? Yes After leaving a printer under room temperature, turn on the power again. Replace the control panel board.

Code: 127

Display: Service call 127: Error
Description: Fuser exhaust fan error
Remedy: Is the fan connector connected normally? Does this error recur? Re-connect it normally. Replace the fan motor. Replace the PU board.

Code: 128

Display: Service call 128: Error
Description: ID cooling fan error
Remedy: Is the fan connector connected normally? Does this error recur?
Re-connect it normally. Replace the fan motor. Replace the PU board.

Code: 131 ... 134

Display: Service call 131: Error~ 134: Error
Description: LED head detection error
(131=Y, 132=M, 133=C, 134=K)
Remedy: Is the LED head connected normally? Is the LED HEAD fuse brown? Does this error recur?
Install the LED head unit normally. Check the LED HEAD fuse. After checking fuse Turn on the power again. For the method of checking the LED head unit fuse

Code: 142

Display: Service call 142: Error
Description: ID Up/Down position detection error
Remedy: Is the ID unit caught by anything when it is removed and re-installed? Does this error recur?
Re-install the ID unit. Turn on the power again. Replace the ID UP/DOWN sensor.

Code: 150 ... 153

Display: Service call 150: Error~ 153: Error
Description: The ID unit fuse has blown out. (150=Y, 151=M, 152=C, 153=K)
Remedy: Is the ID unit installed normally? Does this error recur? Does the printer recover from the error when the PU/PRZ board is replaced?
Re-install the ID unit. Turn on the power again. After checking for the sure connection of the cable between PRZ board and PU board, replace the PRZ board. Replace the PU board.

Code: 154

Display: Service call 154: Error
Description: The belt unit fuse has blown out.
Remedy: Is the belt unit connected normally? Does this error recur?
Re-install the belt unit. Turn on the power again. After checking for the sure cable connection, replace the PU board.