Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi OKI C710n — Trang 6/7

Code: 176, 177

Display: Service call 176: error 177: error
Description: The backup roller thermistor has detected an abnormal temperature (high temperature or low temperature.)
Remedy: Does this error recur? Turn on the power again. Replace the fuser unit. Replace the low voltage power supply unit.

Code: 181, 182

Display: Service call 181: error 182: error
Description: Option unit I/F error (181=Duplex Unit, 182=Option Tray)
Remedy: Does this error recur? Turn on the power again. Check for sure connection of the connectors. Replace the option unit.

Code: 190

Display: Re-start the printer. 190: error
Description: System memory overflow
Remedy: Does this error recur? Yes Turn on the power again. Increase the addon RAM DIMM.

Code: 200, 201, 202

Display: Service call 200: error~ 202: error
Description: PU Firmware Download Error
Error has occurred during rewriting of the PU firmware.
Remedy: After turning on the power again, perform downloading again. (This error does not occur during the normal operation because this processing is not carried out.)

Code: 203, 204, 207, 208

Display: Re-start the printer. 203: error
204: error 207: error 208: error
214: error FOC: error FFF: error
Description: CU program error (The error numbers 203 through 214 do not occur under the normal operation.)
Illegal processing is executed by the CU program.
Remedy: After turning off the power, check for the normal connection between the CU board and the PU board. Then, turn on the power again.

Code: 209

Display: Re-start the printer. 209: Download error
Description: Custom Media Type table downloading has failed
Remedy: After turning on the power again, perform downloading again. (This error does not occur during the normal operation because this processing is not carried out.)

Code: 214, F0C, FFF

Display: Re-start the printer. 203: error
204: error 207: error 208: error
214: error FOC: error FFF: error
Description: CU program error (The error numbers 203 through 214 do not occur under the normal operation.)
Illegal processing is executed by the CU program.
Remedy: After turning off the power, check for the normal connection between the CU board and the PU board. Then, turn on the power again.

Code: 230

Display: Service call 230: error
Description: RFID Reader not Installed
Remedy: RFID read device error Does this error recur?
Check for normal connection of the RFID R/W board. Replace the RFID R/W. Replace the P6 X board.