Description: Low-voltage power supply fan error. Low-voltage power supply temperature error.
Remedy: 1) Is fan in low-voltage power supply unit operating? 2) Error reoccurs after replacing fan motor. Replace fan motor. Replace low-voltage power supply. Replace low-voltage power supply.
Code: 123
Display: Service Call 123: Error
Description: Improper environment humidity detected by sensor.
Remedy: 1) Is error message displayed? 2) Does error reoccur? Turn ON power again. Replace humidity sensor.
Code: 124
Display: Service Call 124: Error
Description: Improper environment temperature detected by sensor.
Remedy: 1) Is error message displayed? 2) Does error reoccur? Turn ON power again. Replace humidity sensor.
Code: 125
Display: Service Call 125: Error
Description: Error detected at MT home position.
Remedy: 1) Is error message displayed? 2) Does error reoccur? Turn ON power again. Replace MT.
Code: 126
Display: Turn power OFF and wait 126: Dew error
Description: Sensor dew error.
Remedy: Sensor dew error detected. Turn ON power after a while.
Code: 130
Display: Service Call 130: Error
Description: Temperature rise detected at LED head.
Remedy: 1) Is error message displayed? 2) Does error reoccur? Leave alone for 30 min. Turn power OFF. Leave for 30 min., then turn power ON. Replace LED head.
Code: 131, 132, 133, 134
Display: Service Call 131: Y Head 132: M Head 133: C Head 134: K Head
Description: Same unit not detected upon power ON or opening cover.
Remedy: 1) Is error message displayed? 2) Is LED head properly set? 3) Does error reoccur? Confirm that LED head is set properly. Turn power ON again. Replace LED head assembly.
Code: 140, 141, 142, 143
Display: Service Call 140: Y ID 141: M ID 142: C ID 143: K ID
Description: Error detected at proper ID position.
Remedy: 1) Is error message displayed? 2) Does error reoccur? Turn power ON again. Replace drum assembly.