Display: Service Call 150: Y 151: M 152: C 153: K
Description: When a fuse could not be disconnected in the ID unit.
Remedy: Is ID unit set properly? Check cable connections and replace engine board.
Display: Service Call 154: Error
Description: When belt unit fuse cannot be disconnected.
Remedy: Is belt unit set properly? Check cable connections and replace engine board.
Display: Service Call 155: Error
Description: When fuser unit fuse cannot be disconnected.
Remedy: Is fuser unit set properly? Check cable connections and replace engine board.
Display: Service Call 160: Y Toner 161: M Toner 162: C Toner 163: K Toner
Description: Error detected by toner sensor.
Remedy: 1) Is error message displayed? 2) Does error reoccur? Replace toner sensor or assembly (Y71-PWB). Same as above.
Display: Service Call 170: Error 171: Error 174: Error 175: Error
Description: Short circuit in fuser thermistor or open detected (high temp. or low temp.)
Remedy: 1) Is error message displayed? 2) Does error reoccur? Turn ON power again. Replace thermistor and turn power OFF. Leave aside for 30 min.
Display: Service Call 172: Error 176: Error
Description: Thermistor indicates high-temperature error.
Remedy: 1) Is error message displayed? 2) Does error reoccur? Turn ON power again. Replace thermistor and turn power OFF. Leave aside for 30 min.
Display: Service Call 173: Error 177: Error
Description: Thermistor indicates low-temperature error.
Remedy: 1) Is error message displayed? 2) Does error reoccur? Turn ON power again. Replace thermistor and turn power OFF. Leave aside for 30 min.
Display: Service Call 179: Error
Description: Wrong fuser standard
Remedy: 1) Does fuser match with model and power voltage? 2) Error reoccurs after setting fuser properly Set proper fuser. Check if fuser is set properly. Replace fuser.