Display: Service Call Power off/on nnn: Fatal Error PC: nnnnnnnn LR: nnnnnnnn FR: nnnnnnnn 002: Error to 007: Error
Description: This stems from a variety of causes.For analyzing causes, record three numbers (called program counting value) indicated below LCD column and a printer firmware version.
Remedy: Record three digital numbers below LCD column. Restart with OFF/ON? Does an error occur in a particular print data? Is the error display reproducible? Is the error display reproducible? Is the error display reproducible? Notify three digital numbers below LCD column and F/W version. Check if it occurs depending on a print data. Request for print data investigation. Change RAM DIMM or ROM DIMM. Replace CU PCB. (Must replace EEPROM) Initialize EEPROM. Re-execute Network setup, such as user setup etc. for use. Change the printer.
Remedy: Is the applicable RAM DIMM mounted properly? Is operation restored by replacing the applicable RAM DIMM? Re-mount applicable RAM DIMM. Replace RAM DIMM. Replace CU PCB. (Must replace EEPROM)
Description: Slot2 RAM Spec error Specification of DIMM in CU RAM slot2 is unsupported.
Remedy: Is this a standard RAM DIMM? Is the applicable RAM DIMM difference mounted normal? Is operation restored by replacing the applicable RAM DIMM? Use a standard RAM DIMM. Re-mount applicable RAM DIMM. Replace RAM DIMM. Replace CU PCB. (Must replace EEPROM)
Remedy: Is the problem corrected by replacing the CU PCB EEPROM? REPLACE EEPROM. (User must correct environmental conditions) Replace CU PCB. (Must replace EEPROM)