Remedy: 24 V of power is not supplied to tray 5 properly. Check to confirm that tray 5 is mounted correctly.
Code: 928
Display: Power Off/on 928: Error
Description: Fuser Motor Lock Error
Remedy: The fuser is not operating properly. Does the error still occur? Check to confirm that the fuser is in position. Replace the fuser. Replace the fuser motor.
Code: 929
Display: Power Off/on 929: Error
Description: Waste Toner Transfer Motor Lock Error
Remedy: The waste toner transfer motor is not operating properly. Does the error still occur? Check to confirm that the waste toner transfer system is operating properly. Replace the waste toner motor.
Code: 930
Display: Power Off/on 930: Error
Description: Sub-CPU Clock Frequency Error The Sub-CPU clock frequency is not correct.
Remedy: The Sub-CPU clock frequency is not correct. Does the error still occur? Check the connection of the S2P board. Replace the S2P board.
Code: 931
Display: Power Off/on 931: Error
Description: Duplex CPU Clock Frequency Error
Remedy: The duplex CPU clock frequency is not correct.Does the error still occur? Check the connection of the V72-18 board. Replace the V72-18 board.
Code: 932
Display: Power Off/on 932: Error
Description: Inverter CPU Clock Frequency Error
Remedy: The inverter CPU clock frequency is not correct. Does the error still occur? Check the connection of the V72-13 board. Replace the V72-13 board.
Code: 933
Display: Power Off/on 933: Error
Description: Trya2 CPU Clock Frequency Error
Remedy: The tray-2 CPU clock frequency is not correct. Does the error still occur? Check the connection of the V72-17 board of tray 2. Replace the V72-17 board.
Code: 934
Display: Power Off/on 934: Error
Description: Trya3 CPU Clock Frequency Error
Remedy: The tray-3 CPU clock frequency is not correct. Does the error still occur? Check the connection of the V72-17 board of tray 3. Replace the V72-17 board.