Mã lỗi OKI C910 — Trang 3/11
Code:
Tất cả lỗi (85)
001
002 ... 007
025
030
031
037
040
041
042 ... 045
048
049
050
051
052
060
062
063
070
072
073 ... 075
081
096
097
104
105
106
111 ... 117
121
123
124
125
126
128
131 ... 134
140 ... 142
144 ... 147
150 ... 153
154
155
160 ... 163
167
168
169
170 ... 175
172 ... 176
173 ... 177
179
180 ... 186
187
188
189
190
200, 201, 202
203, 204, 207, 213
209
230
231
240 ... 245
247, 248
250
251
910 ... 914
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
940
983
F0C, F0D, FFE, FFF
Display: Power Off/on 063: Error
Description: Network comm. Error H/W I/F abnormality between CU-NIC.
Remedy: Does replacement of the network PCB correct the problem? No Yes No Properly mount Replace Network Replace CU PCB. (Must replace EEPROM)
Display: Power Off/on 070: Error
Description: CANT_HAPPEN PS Firmware Abnormality Detection
Remedy: Check if problem is corrected by turning OFF/ON Power/ No Replace CU PCB. (Must replace EEPROM)
Display: Power Off/on 072: Error
Description: Engine communication error I/F Error between PU-CU.
Remedy: Is the CU Assy properly mounted? Does replacement of the CU PCB correct the problem? Properly mount Replace CU PCB. (Must replace EEPROM) Replace PU PCB
Display: Power Off/on 073: Error to 075: Error
Description: Video overrun detect
Remedy: Is the CU Assy properly mounted? Does replacement of the CU PCB correct the problem? Properly mount Replace CU PCB. (Must replace EEPROM)
Display: Service Call 081: Error
Description: Parameter Match Check Error
Remedy: Normal Read/Write not possible with EEPROM or Flash. If the condition does not change replace CU PCB.
Display: Service Call 096: Error
Description: Finisher Unrestorable Error
Remedy: Is the error display reproducible? If turning OFF and ON the power again does not correct the problem, maintenance by a servicing personnel is necessary.
Display: Service Call 097: Error
Description: Inverter power supply Error
Remedy: Is the error display reproducible? If turning OFF and ON the power again does not correct the problem, maintenance by a servicing personnel is necessary.
Display: Service Call 104: Error
Description: When turning ON the power, detected error in engine EEPROM test total.
Remedy: Does the Error take place again? Replace engine control PCB (S2X).