Remedy: Does error display reappear? Refer to no LCD display flow chart.
Code: 051
Display: Service Call 051: Error
Description: CU Fan Error Abnormal CPU cooling fan on CU board.
Remedy: Is connector set properly on CU board? Is error recovered by replacing fan? Connect properly. Replace fan. Replace TIG board. (Replace EEPROM.)
Code: 063
Display: Service Call 063: Error
Description: Network comm. Error Abnormal H/W I/F between CU-NIC.
Remedy: Is network board set properly? Is error recovered by replacing network board? Set properly. Replace Network. Replace TIG board. (Replace EEPROM.)
Code: 065
Display: Service Call 065: Error
Description: NIC Combination Error
Remedy: Is proper Network board for the model set? Replace NIC card. Replace with proper Network board (MLETB11, etc.).
Code: 070
Display: Service Call 070: Error
Description: CANT_HAPPEN PS firmware fault detected. Confirm that error is recovered by turning power OFF/ON.
Remedy: Confirm that error is recovered by turning power OFF/ON. Replace TIG board. (Replace EEPROM.)
Code: 072
Display: Service Call 072: Error
Description: Engine communication error I/F error between PU-CU.
Remedy: Is CU assembly set properly? Is error recovered by replacing TIG board? Set properly. Replace TIG board. (Replace EEPROM.) Replace PU board.
Code: 073, 074, 075
Display: Service Call 073: Error ~ 075: Error
Description: Video overrun detect
Remedy: Is CU assembly set properly? Is error recovered by replacing TIG board? Set properly. Replace TIG board. (Replace EEPROM.)
Code: 090
Display: Service Call 090: Error
Description: Finisher Stapler Motor Error
Remedy: Is the error message displayed again? See Finisher Maintenance Manual.