Các lỗi thường gặp

Code :
  • Code: 106
  • Display: Service Call 106: Error
  • Description: Error in engine control logic detected at power ON.
  • Remedy: Does error reoccur? Replace engine control board (K7N).
  • Code: 107
  • Display: Service Call 107: Error
  • Description: Engine ROM check sum error.
  • Remedy: Does error reoccur? Is error recovered by reloading PU F/W?
    Reload PU I/F. Replace engine control board (K7N).
  • Code: 110 ... 116
  • Display: Service Call 110: Error ~ 116: Error
  • Description: Option unit for different model detected. 110: EnvelopeFeeder 111: Duplex unit 112: 2nd Tray 113: 3rd Tray 114: 4th Tray 115: 5th Tray 116: Finisher
  • Remedy: Is a proper option unit for the printer set? Set proper option unit. Check connections and turn power ON. If error is not recovered, replace the unit.
  • Code: 120
  • Display: Service Call 120: Error
  • Description: PU unit fan motor error.
  • Remedy: 1) Is fan in PU unit operating? 2) Error reoccurs after replacing fan motor.
    Replace fan motor. Replace engine control board (K7N). Replace engine control board (K7N).
  • Code: 121
  • Display: Service Call 121: Error
  • Description: High-voltage power supply I/F error.
  • Remedy: Is cable between PU board andhighvoltage power LSI connected properly?
    Connect properly. Replace high-voltage power supply. Check improper connections for high-voltage.
  • Code: 122
  • Display: Service Call 122: Error
  • Description: Low-voltage power supply fan error. Low-voltage power supply temperature error.
  • Remedy: 1) Is fan in low-voltage power supply unit operating? 2) Error reoccurs after replacing fan motor.
    Replace fan motor. Replace low-voltage power supply. Replace low-voltage power supply.
  • Code: 123
  • Display: Service Call 123: Error
  • Description: Improper environment humidity detected by sensor.
  • Remedy: 1) Is error message displayed? 2) Does error reoccur?
    Turn ON power again. Replace humidity sensor.
  • Code: 124
  • Display: Service Call 124: Error
  • Description: Improper environment temperature detected by sensor
  • Remedy: 1) Is error message displayed? 2) Does error reoccur?
    Turn ON power again. Replace humidity sensor.