Remedy: The tray-2 CPU clock frequency is not correct. Does the error still occur? Check the connection of the V72-1 board of tray 2. Replace the V72-1 board.
Remedy: The tray-3 CPU clock frequency is not correct. Does the error still occur? Check the connection of the V72-1 board of tray 3. Replace the V72-1 board.
Remedy: The tray-4 CPU clock frequency is not correct. Does the error still occur? Check the connection of the V72-1 board of tray 4. Replace the V72-1 board.
Remedy: The tray-5 CPU clock frequency is not correct. Does the error still occur? Check the connection of the V72-1 board of tray 5. Replace the V72-1 board.
Remedy: The transfer mechanism of the toner duct for ID is not operating properly. Does the error still occur? Check to confirm that the basket assembly is in position (if it is engaged with the gear of the printer). Check to confirm that the holder magnet D contains a magnet, and check the magnetic polarity. Replace the HAL IC circuit board. Replace the duct assembly toner.
Display: Service Call 203: Error to 208: Error 210: Error to 214: Error 0xFOC: Error 0xFOD: Error 0xFFE: Error 0xFFF: Error
Description: CU Program Dysfunction Detected illegal process with CU program.
Remedy: Detected illegal process with CU program. Write down the 24 digit number displayed on the LCD panel and report it. Turn OFF the power. Then check the insertion of the CU board. Now turn ON the power again.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.