Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi OKI C9600 — Trang 8/15

Code: 187

Display: Service Call 187: Error
Description: Communication with control panel failed.
Remedy: Is the control panel and cable connected properly?
Connect properly Replace the control panel and cable.

Code: 188

Display: Service Call 188: Error
Description: Sub-CPU I/F Error
Remedy: Sub-CPU Communication Error. Check the connection of the S2M board. Replace the S2M board.

Code: 189

Display: Service Call 189: Error
Description: Inverter Unit I/F Error
Remedy: 1) Inverter communications error 2) Does the Error take place again? Check the connection of the I/F cable. Replace the V72-3 board.

Code: 190

Display: Service Call 190: Error
Description: System Memory Overflow
Remedy: System Memory Overflow. Power OFF/ON Replace CU PCB. (Replace EEPROM)

Code: 200 ... 202

Display: Service Call 200: Error to 202: Error
Description: PU Firm Download Error
Error occurred when downloading PU firmware.
Remedy: Error occurred when downloading PU firmware. After turning ON the power again, try downloading again. (This process isn’t executed for regular operations, therefore, will not occur)

Code: 203, 208, 210, 214

Display: Service Call 203: Error to 208: Error
210: Error to 214: Error 0xFOC: Error 0xFOD: Error 0xFFE: Error 0xFFF: Error
Description: CU Program Dysfunction
Detected illegal process with CU program.
Remedy: Detected illegal process with CU program. Write down the 24 digit number displayed on the LCD panel and report it. Turn OFF the power. Then check the insertion of the CU board. Now turn ON the power again.

Code: 209

Display: POWER OFF/ON 209: DOWNLOAD ERROR
Description: Custom Media Table Download Error
Failed to download custom media table.
Remedy: Failed to download custom media table. After turning ON the power again, try downloading again. (This process isn’t executed for regular operations, therefore, will not occur)

Code: 220

Display: Service Call 220: Error
Description: Print Satistic mismatch
HDD was removed or replaced after print statistic is set to ON.
Remedy: HDD was removed or replaced after print statistic is set to ON. Get the original HDD back.