Causes: Auto toner sensor Harness LGC board Developer material
Remedy: 1 <Color toner low density> Check the printing status. Is the color printing ratio 5% or more? Yes 2 No The color toner low density might be the cause. Turn the code 08-2692 "Prevention of color toner low density / ON/OFF setting" to ON, and then set number of sheets to be judged at the code 08- 2693 "Prevention of color toner low density/Judged number of sheets setting". 2 Developer unit • Check if the developer unit is installed properly. • Check that the developer unit and coupling on the equipment side are properly engaged. • Check that the mixer of the developer unit is rotated. • Check if the developer material is too light visually. • Check if the amount of the developer material is too large or too small. 3 EPU • Remove any toner or dust on the ATC sensor connector and the drawer connector of the process cover. • Remove any toner or dust on the EPU sensor connector and the drawer connector on the equipment side. 4 Auto toner sensor Harness LGC board • Check the connectors and harnesses between the auto toner sensor and LGC board (CN340). • Check if there is any foreign matter such as toner in the connector of the auto toner sensor. Remove if there is and reconnect it.
Causes: Auto toner sensor Harness LGC board Developer material
Remedy: 1 <Color toner low density> Check the printing status. Is the color printing ratio 5% or more? Yes 2 No The color toner low density might be the cause. Turn the code 08-2692 "Prevention of color toner low density / ON/OFF setting" to ON, and then set number of sheets to be judged at the code 08- 2693 "Prevention of color toner low density/Judged number of sheets setting". 2 Developer unit • Check if the developer unit is installed properly. • Check that the developer unit and coupling on the equipment side are properly engaged. • Check that the mixer of the developer unit is rotated. • Check if the developer material is too dark visually. • Check if the amount of the developer material is too large or too small. 3 EPU • Remove any toner or dust on the ATC sensor connector and the drawer connector of the process cover. • Remove any toner or dust on the EPU sensor connector and the drawer connector on the equipment side. 4 Auto toner sensor Harness LGC board • Check the connectors and harnesses between the auto toner sensor and LGC board (CN340). • Check if there is any foreign matter such as toner in the connector of the auto toner sensor. Remove if there is and reconnect it.
Causes: Auto toner sensor Harness LGC board Developer material
Remedy: 1 <Color toner low density> Check the printing status. Is the color printing ratio 5% or more? Yes 2 No The color toner low density might be the cause. Turn the code 08-2692 "Prevention of color toner low density / ON/OFF setting" to ON, and then set number of sheets to be judged at the code 08- 2693 "Prevention of color toner low density/Judged number of sheets setting". 2 Developer unit • Check if the developer unit is installed properly. • Check that the developer unit and coupling on the equipment side are properly engaged. • Check that the mixer of the developer unit is rotated. • Check if the developer material is too light visually. • Check if the amount of the developer material is too large or too small. 3 EPU • Remove any toner or dust on the ATC sensor connector and the drawer connector of the process cover. • Remove any toner or dust on the EPU sensor connector and the drawer connector on the equipment side. 4 Auto toner sensor Harness LGC board • Check the connectors and harnesses between the auto toner sensor and LGC board (CN340). • Check if there is any foreign matter such as toner in the connector of the auto toner sensor. Remove if there is and reconnect it.
Description: Thermistor / heater lamp abnormality at power-ON
Causes: Power supply unit. LGC board
Remedy: Power voltage Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) Thermopiles • Check if the fuser belt center and side thermopiles (front, rear) are installed properly. • Check if the harnesses of the fuser belt center and side thermopiles (front, rear) are open circuited. Power supply unit and fuser unit • Is the fuser unit installed correctly? • Check if the heater lamp is broken. • Check if the connector of the heater lamp is disconnected. • Check if the thermostat is blown • Check if the connectors of the power supply unit are disconnected (power supply unit AC output connector CN408, CN409 and LGC I/F connector CN404 CN405). • Check if the power supply unit is abnormal. LGC board • Check if the connectors CN333, CN345 and CN361 are disconnected. • Check if the conductor pattern on the LGC board is short circuited or open circuited. Status counter After repairing the matter which caused the error [C411/C412], perform the following: • Turn ON the power while [0] and [8] are pressed simultaneously • Key in “2002”, then press [START]. • Change the current status counter value “1 “ or “2 “ to “0”, then press [OK] or [INTERRUPT] (to cancel [C411/C412]). • Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
Description: Heater lamp abnormality after abnormality judgment
Causes: Power supply unit. LGC board
Remedy: 1,2,3,4. Check the thermopiles, Heater and LGC board Check the above components following the procedures 1, 2,3 and 4 for [C411/C412]. 5 Clear the status counter Change the current status counter value (08-2002) “3”, “5”, “6”, “9”, “19”, “21”, “22”, “23”, “24”, “25”, “27”, “29” or “32” to “0” for [C44X], taking the same procedure as that for [C41X]. * The status counter value is as follows in the following cases. - The error occurred during warming-up: “3”, “5” or “6” The error occurred after the equipment has become ready: “7”. - The temperature detected by the fuser belt center thermopile is 220°C or higher, the temperature detected by the side thermopile is 230°C or higher or the temperature detected by the front thermopile is 250°C or higher: “9”, “19”, “21”, “22”, “23”, “25”, “27” or “29” - The error occurred during printing: “24” or “25”. - The error occurred during energy saving: “27”. - A paper jam occurred: “29”.
Description: Heater lamp abnormality after abnormality judgment
Causes: Power supply unit. LGC board
Remedy: 1,2,3,4. Check the thermopiles, Heater and LGC board Check the above components following the procedures 1, 2,3 and 4 for [C411/C412]. 5 Clear the status counter Change the current status counter value (08-2002) “3”, “5”, “6”, “9”, “19”, “21”, “22”, “23”, “24”, “25”, “27”, “29” or “32” to “0” for [C44X], taking the same procedure as that for [C41X]. * The status counter value is as follows in the following cases. - The error occurred during warming-up: “3”, “5” or “6” The error occurred after the equipment has become ready: “7”. - The temperature detected by the fuser belt center thermopile is 220°C or higher, the temperature detected by the side thermopile is 230°C or higher or the temperature detected by the front thermopile is 250°C or higher: “9”, “19”, “21”, “22”, “23”, “25”, “27” or “29” - The error occurred during printing: “24” or “25”. - The error occurred during energy saving: “27”. - A paper jam occurred: “29”.
Description: Heater lamp lights continuously for a certain period of time when the pressure roller temperature during ready status is higher than the specified
Causes: Power supply unit. LGC board
Remedy: Power supply and fuser unit • Check if the fuser unit is installed properly • Check if foreign matter or paper in the fuser unit is plugging up the monitoring opening of the fuser belt thermopile. • Check if there is any stain on sensor area of the fuser belt thermopile. • Check if the opening of the fuser belt thermopile of the equipment is plugged up. • Check if the connectors of the power supply are disconnected (CN404, CN405, CN408, CN409). • Check if the power supply unit is abnormal. LGC board • Check if the connector CN333 is disconnected. • Check if the conductor pattern on the LGC board is short circuited or open circuited. Status counter After repairing the matter which caused the error [C448], perform the following: 1. Turn the power ON while [0] and [8] are pressed simultaneously. 2. Key in “2002”, then press the [START] button. 3. Change the displayed current status counter value “32” to “0”, then press [OK] or [INTERRUPT] (to cancel C448). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal status.
Description: [C450/C451] Abnormal temperature difference between the center thermopile and the edge thermistor [C452] Abnormal thermopile temperature diffe
Causes: Power supply unit Thermopile LGC board
Remedy: Power supply and fuser unit • Check if the fuser unit is installed properly. • Check if foreign matter or paper in the fuser unit is plugging up the monitoring opening of the thermopile. • Check if there is any stain on sensor area of the fuser belt thermopile. • Check if the heater lamp is open circuited. • Check if the connector of the heater lamp is disconnected. • Check if the thermistor is open circuited. • Check if the connectors of the power supply unit (power supply unit AC output connector CN408, CN409 and LGC/IF connector CN404, CN405) are disconnected. • Check if the power supply unit is broken. Thermopile • Check if foreign matter is plugging up the thermopile. • Check if the thermopile is installed properly. • Check if the harnesses are open circuited. LGC board • Check if the connectors CN333, CN345 and CN361 are disconnected. • Check if the conductor pattern on the LGC board is short circuited or open circuited. Status counter 1. Turn the power ON while [0] and [8] are pressed simultaneously. 2. Key in “2002”, then press the [START] button. 3. Reset the displayed current status counter value "38", "39", "41", "42", "48", "49", "50" or "51" to "0", then press [OK] or [INTERRUPT]. (The error C451 or C452 is cleared.) 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal status.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.