Description: Toner sensor detection error (160=Y, 161=M, 162=C, 163=K) This error does not occur with the factory default settings.
Remedy: Is the toner cartridge installed? Is the lock lever of the toner set? Does this error recur? Install the toner cartridge. Move the lock lever of toner cartridge to the lock position. Replace the toner sensor assembly.
Description: An abnormality was detected with the power supply temperature thermistor. 01: Short 02: Open 03: High temp. 04: Low temp.
Remedy: 01, 02: Does this error recur? Does this error recur? Does this error recur? Restore the power. Replace the low voltage power supply unit. Replace the CU/ PU board. Replace the cable between the low voltage power supply unit and the CU/PU board. 03: Does this error recur? Remove anything obstructing the ventilation slots if any and restore the power. Replace the low voltage power supply unit. Replace the CU/ PU board. Replace the cable between the low voltage power supply unit and the CU/PU board. 04: Does this error recur? Raise the room temperature and restore the power. Replace the low voltage power supply unit. Replace the CU/ PU board. Replace the cable between the low voltage power supply unit and the CU/PU board.
Description: An either temperature aberration (a hightemperature or cold temperature) of Upper Center Thermistor, Lower Thermistor, Upper Side Thermistor, Planar Heater Thermistor was detected.
Remedy: Does this error recur? Yes Restore the power. Replace the fuser unit.