Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi OKI ES8431 — Trang 9/11

Code: 903, 904

Display: Power off/on 903: Error, 904: Error
Description: The belt thermistor detected abnormal (too high or too low) temperature.
Remedy: Is the belt thermistor cable connected properly? Does this error recur?
Re-connect the cable properly and restore the power. Replace the belt thermistor, after a lapse of 30 minutes, turn on the power.

Code: 918

Display: Power off/on 918: Error
Description: Duplex FAN error
Remedy: Does this error recur after power restoration? Does this error recur after power restoration? Does this error recur after power restoration?
Check if the duplex unit is installed properly. Check if the FAN is connected properly. Replace the FAN.

Code: 923

Display: Power off/on 923: Error
Description: The ID motor is not running normally.
Remedy: Does this error message reappear after power restoration? Does this error message reappear after power restoration?
Check if the image drum is installed properly. Replace the image drum unit. Replace the ID motor.

Code: 928

Display: Power off/on 928: Error
Description: The fuser motor is not running normally.
Remedy: Does this error message reappear after power restoration? Does this error message reappear after power restoration?
Check if the fuser is installed properly. Replace the fuser. Replace the fuser motor.

Code: 931

Display: Power off/on 931: Error
Description: Duplex unit CPU clock frequency error
Remedy: Does this error message reappear after power restoration? Does this error message reappear after power restoration?
Replace the unit. Replace the CU/ PU board.

Code: 933

Display: Power off/on 933: Error
Description: Tray 2 CPU clock frequency error
Remedy: Does this error message reappear after power restoration? Does this error message reappear after power restoration?
Replace the unit. Replace the CU/ PU board.

Code: 934

Display: Power off/on 934: Error
Description: Tray 3 CPU clock frequency error
Remedy: Does this error message reappear after power restoration? Does this error message reappear after power restoration?
Replace the unit. Replace the CU/ PU board.

Code: 935

Display: Power off/on 935: Error
Description: Tray 4 CPU clock frequency error
Remedy: Does this error message reappear after power restoration? Does this error message reappear after power restoration?
Replace the unit. Replace the CU/ PU board.