Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi OKI ES8431 — Trang 10/11

Code: 941

Display: Power off/on 941: Error
Description: A watch dog timer error was detected.
Remedy: Does this error recur? Yes Cycle the power. Replace the CU/ PU board.

Code: 942

Display: Power off/on 942: Error
Description: An undefined interruption was detected.
Remedy: Does this error recur? Yes Cycle the power. Replace the CU/ PU board.

Code: 943

Display: Power off/on 943: Error
Description: PU CPU ran away out of control due to noise etc.
Remedy: Does this error recur? Yes Cycle the power. Replace the CU/ PU board.

Code: 944

Display: Power off/on 944: Error
Description: Dcon circuit access failed.
Remedy: Does this error recur? Yes Cycle the power. Replace the CU/ PU board.

Code: 945

Display: Power off/on 945: Error
Description: SDRAM access at power on failed.
Remedy: Does this error recur? Yes Cycle the power. Replace the CU/ PU board.

Code: 980

Display: Power off/on 980: Error
Description: An abnormal temperature of the fuser unit was detected.
Remedy: Does this error recur? Yes Cycle the power. Replace the fuser unit.

Code: 982

Display: Service call 982: Error
Description: Excessive trays beyond the specification are installed.
Remedy: Are many trays beyond the specification installed? Yes Use trays as many as specified.

Code: 983

Display: Service call 983: Error
Description: More than one toner cartridge tag of the same color was detected.
Remedy: Does this error recur? Yes Cycle the power. Replace the CU/ PU board.