Remedy: Is LED head properly set? Does error reoccur? Set properly for LED head unit. Turn power ON agein. Replace LED head unit
Code: 155
Description: Fuser unit fuse cannot be disconnected.
Remedy: Is fuser unit set properly? Does error reoccur? After cleaning for fuser connector, reset. Turn power ON again. Replace the PU/ CU board.
Code: 163
Description: Error detected by toner sensor. (163=K) This error does not occur with the factory default settings.
Remedy: Is toner cartridge setting? Is toner lock lever setting? Does error reoccur? Set toner cartridge. Turn a lock lever of toner to a fixed position. Replace toner sensor or assembly.
Code: 166
Description: An abnormality was detected with the power supply temperature thermistor. 01: Short 02: Open 03: High temp. 04: Low temp.
Remedy: 01, 02: Does error reoccur? Does error reoccur? Does error reoccur? 03: Does error reoccur? Does error reoccur? Does error reoccur? 04: Does error reoccur? Does error reoccur? Does error reoccur? Power Off/On. Replace the low voltage power supply unit. Replace the PU/ CU board. Replace the cable between the low voltage power supply unit and the PU/CU board. Remove anything obstructing the ventilation slots if any and restore the power. Replace the low voltage power supply unit. Replace the PU/ CU board. Replace the cable between the low voltage power supply unit and the PU/CU board. Raise the room temperature and restore the power. Replace the low voltage power supply unit. Replace the PU/ CU board. Replace the cable between the low voltage power supply unit and the PU/CU board.
Code: 167
Description: ThermistorSlope Error
Remedy: Is the error message displayed? Does error reoccur? Power Off/On. After leaving the printer for 30 minutes, turn on the printer again.
Code: 168
Description: Compensation Thermistor Error 01: Short 02: Open 03: High temp. 04: Low temp.
Remedy: Is the error message displayed? Does error reoccur? Power Off/On. After leaving the printer for 30 minutes, turn on the printer again.
Code: 169
Description: Upper Side Thermistor Error 01: Short 02: Open 03: High temp. 04: Low temp.
Remedy: Is the error message displayed? Does error reoccur? Power Off/On. After leaving the printer for 30 minutes, turn on the printer again.
Code: 170, 171
Description: Short circuit in fuser thermistor or open detected.
Remedy: Does error reoccur? Yes Power Off/On. Replace the fuser unit.