Code :
  • Code: 063
  • Display: Power Off/on 063: Error
  • Description: Network comm. Error H/W I/F abnormality between CU-NIC.
  • Remedy: Does replacement of the network PCB correct the problem? No Properly mount Yes Replace Network No Replace CU PCB. (Must replace EEPROM)
  • Code: 070
  • Display: Power Off/on 070: Error
  • Description: CANT_HAPPEN PS Firmware Abnormality Detection
  • Remedy: Check if problem is corrected by turning OFF/ON Power/ No Replace CU PCB. (Must replace EEPROM)
  • Code: 072
  • Display: Power Off/on 072: Error
  • Description: Engine communication error I/F Error between PUCU.
  • Remedy: Is the CU Assy properly mounted? No Properly mount Does replacement of the CU Yes Replace CU PCB. (Must replace EEPROM) PCB corrects the Replace PU PCB
  • Code: 073 ... 075
  • Display: Power Off/on 073: Error to 075: Error
  • Description: Video overrun detect
  • Remedy: Is the CU Assy properly mounted? No Properly mount Does replacement of the CU PCB corrects the problem? Yes Replace CU PCB. (Must replace EEPROM)
  • Code: 081
  • Display: Service Call 081: Error
  • Description: Parameter Match Check Error
  • Remedy: Normal Read/Write not possible with EEPROM or Flash. If the condition does not change replace CU PCB.
  • Code: 0xFOC, 0xFOD, 0xFOD, 0xFFE, 0xFFF
  • Display: Service Call 203: Error 204: Error 207: Error to 213: Error Power Off/on nnn: p 0xFOC: Error 0xFOD:Error 0xFFE:Error 0xFFF:Error
  • Description: CU Program Dysfunction
  • Remedy: Detected illegal process with CU program. Yes Write down the 24 digit number displayed on the LCD panel and report it. Turn OFF the power. Then check the insertion of the CU board. Now turn ON the power again.
  • Code: 104
  • Display: Service Call 104: Error
  • Description: When turning ON the power, detected error in engine EEPROM test total.
  • Remedy: Does the Error take place again? Replace engine control PCB (S2X).
  • Code: 105
  • Display: Service Call 105: Error
  • Description: When turning ON the power, failed to detect the EEPROM (presence).
  • Remedy: Is there an EEPROM? Yes Mount an EEPROM. No Mount the EEPROM. Does the Error take place again? Yes Replace engine control PCB (S2X )