Code: 106

Display: Service Call 106: Error
Description: Error detected in engine control logic.
Remedy: Does the Error take place again? Yes Replace engine control PCB (S2X).

Code: 111 ... 117

Display: Service Call 111: Error to 117: Error
Description: An optional unit for another model was detected. 111: Duplex unit, 112: 2nd Tray, 113: 3rd Tray, 114: 4thTray, 115: 5th Tray, 116: Finisher, 117: Inverter
Remedy: Is the proper optional unit for that model mounted? No Mount the proper optional unit. Check the connection. Then turn ON the power again. No Replace the unit if operations are not restored.

Code: 121

Display: Service Call 121: Error
Description: Low Voltage Power FAN Error
Remedy: 1) Is the PU PCB high voltage power cable properly connected? No Connect properly Yes Check to see if there is any contact-defects in the high voltage system. Replace High Voltage Power Unit 2) Does the Error take place again?

Code: 123

Display: Service Call 123: Error
Description: Sensor detects an inappropriate relative humidity for the operating environment.
Remedy: 1) Is an Error message displayed? Yes Turn ON power again. 2) Does the Error take place again? Yes Replace the environmental sensor.

Code: 124

Display: Service Call 124: Error
Description: Sensor detects an inappropriate room temperature for the operating environment.
Remedy: 1) Is an Error message displayed? Yes Turn ON power again. 2) Does the Error take place again? Yes Replace the environmental sensor.

Code: 125

Display: Service Call 125: Error
Description: Error detected in MPT home position.
Remedy: 1) Is an Error message displayed? Yes Turn ON power again. 2) Does the Error take place again? Yes Replace MPT

Code: 126

Display: Turn OFF the power and wait. 126: Dew Error
Description: Sensor Dew Error
Remedy: Sensor Dew Error Detected Wait a while then turn ON power again.

Code: 128

Display: Service Call 128: Error
Description: Engine FAN Motor Error
Remedy: Error was detected in each fan. 01: Fuser FAN Error 02: Power FAN Error 03: PU Motor FAN Error 04: Belt FAN Error 05: IDFAN Error 06: Top Cover FAN Error Is the applicable location of the fan connection normal? If the condition does not change. Replace fan.