Description: TD sensor initial setting error
TD sensor output voltage falls out of the adjustment range (2.0 +- 0.2 V) after the TD sensor initial setting has been finished.
Causes: • Someone forgot to remove the toner seal of the PCU • ID sensor defective • TD sensor abnormal • Drum does not turn • Development roller does not turn • Poor connection of the PCU
Description: Transfer roller leak error 1
A transfer roller current leak signal is detected. The current feedback signal for the transfer roller is not detected.
Causes: • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
Description: Transfer roller leak error 2
A transfer roller current leak signal is detected. The current feedback signal for the transfer roller is not detected.
Causes: • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
Description: Main motor lock
A main motor lock signal is not detected for more than 500 ms after the main motor starts to rotate, or the lock signal is not detected for more than 500 ms during rotation after the last signal.
Causes: • Too much load on the drive mechanism • Main motor defective