Mã lỗi Ricoh Aficio 1027 — Trang 10/13
Description: Self-diagnostic Error: NVRAM/Optional NVRAM
The NVRAM or optional NVRAM returned an error during the self-diagnostic test.
Causes: Replace the NVRAM on the controller board
Description: Self-diagnostic Error: RAM
The resident RAM returned a verify error during the self-diagnostic test.
Causes: Download controller firmware again
Description: Self-diagnostic Error: ROM
The resident read-only memory returned an error during the self-diagnostic test.
Causes: • Controller board defective • Download controller firmware again
Description: Self-diagnostic Error: Optional RAM
The optional RAM returned an error during the self-diagnostic test.
Causes: • Replace the optional memory board • Controller board defective
Description: Self-Diagnostic Error: Parallel Interface
Loopback test error.
Causes: • Loopback connector not detected • IEEE1284 connector defective • Controller board defective
Description: Self-diagnostic Error: Resident Font ROM
The resident font ROM returned an error during the self-diagnostic test.
Causes: Replace the controller board
Description: Self-diagnostic Error: Optional Font ROM
The optional font ROM returned an error during the self-diagnostic test
Causes: Replace the controller board
Description: Self-diagnostic Error: Clock Generator
A verify error occurred when setting data was read from the clock generator via the I2C bus.
Causes: Replace the controller board