Các lỗi thường gặp

Code :
  • Code: 900
  • Description: Electronic total counter error
    The value of the total counter has already exceeded 9999999
  • Causes: Replace the NVRAM on the controller board
  • Code: 901
  • Description: Mechanical total count error
    The SBCU board cannot receive the mechanical total count data.
  • Causes: Mechanical total counter defective
  • Code: 951
  • Description: F-gate error at write request
    After the IPU receives an F-gate signal, it receives another F-gate signal.
  • Causes: • Download controller firmware • SBCU board defective
  • Code: 953
  • Description: Scanner setting error
    The IPU does not respond with the scanner setting signal required to start scanning processing.
  • Causes: Download controller firmware
  • Code: 954
  • Description: Printer setting error
    The IPU does not respond with the settings that are required to start image processing by the printer.
  • Causes: • Replace the IPU board • Replace the controller board • Download the controller firmware
  • Code: 955
  • Description: Memory setting error
    The IPU does not respond with the settings that are required to start image processing using the memory.
  • Causes: • Replace the IPU board • Replace the controller board • Download the controller firmware
  • Code: 964
  • Description: Printer ready error
    The printer ready signal is not generated within 17 seconds after the IPU received the print start signal.
  • Causes: • Replace the IPU board • Replace the controller board • Download the controller firmware
  • Code: 984
  • Description: Print image data transfer error
    The image transfer from the controller to the engine via the PCI bus does not end within 15 s after starting.
  • Causes: • Controller board defective • SBCU board defective • Connectors between SBCU and controller loose or defective