Mã lỗi Ricoh Aficio 1035 — Trang 12/15
Description: Self-diagnostic Error: Optional RAM
The optional RAM returned an error during the self-diagnostic test.
Causes: • RAM DIMM defective • Controller board defective
Description: Self-Diagnostic Error: Parallel Interface
Loopback test error.
Causes: • Loopback connector not detected • IEEE1284 connector defective • Controller board defective
Description: Self-diagnostic Error: Resident Font ROM
The resident font ROM returned an error during the self-diagnostic test.
Causes: • Font ROM defective
Description: Self-diagnostic Error: Optional Font ROM
The optional font ROM returned an error during the self-diagnostic test.
Causes: • Font ROM defective
Description: Self-diagnostic Error: Clock Generator
Verify error occurred when setting data was read from the clock generator via the I2C bus.
Causes: • Clock generator abnormal • I2C bus abnormal • CPU port for the I2C bus abnormal
Description: Network I/F Abnormal
Causes: • NIB defective • Controller board defective
Description: IEEE 1394 I/F Abnormal
Causes: • IEEE1384 interface board defective • Controller board defective
Description: Startup without HD connection at main power on
The hard disk connection is not detected.
Causes: • Cable between HDC and HD loose or defective • HD power connector loose or defective • HD defective • HDC defective