Description: Polygonal mirror motor error 3
The XSCRDY signal becomes high while the polygonal mirror motor turns on, even though there was no demand for either turning off the motor or changing the motor speed.
Causes: • Poor cable connection to the polygonal mirror motor driver. • Polygonal mirror motor (driver) defective • BICU defective
Description: Polygonal mirror motor error 1
The XSCRDY signal does not become stable within 20 seconds after the polygonal mirror motor turns on or off or the polygon motor speed is changed.
Causes: • Poor cable connection to the polygonal mirror motor driver. • Polygonal mirror motor (driver) defective • BICU defective
Description: TD sensor output error
The TD sensor output voltage (Vt), which is measured during each copying process, is one of the following 10 times consecutively. 1) Vt = 0.5 volts or lower 2) Vt = 4.0 volts or higher
Causes: • TD sensor defective • Poor connection between the TD sensor and the I/O board. • I/O board defective NOTE: In this error condition, the toner supply is controlled using pixel count and Vsp/Vsg.
Description: TD sensor adjustment error 1
During the TD sensor auto adjustment, the TD sensor output voltage (Vt) is 2.5 volts or higher even though the control voltage is set to the minimum value (PWM = 0)
Causes: • TD sensor defective • Poor connection between the TD sensor and the I/O board. • I/O board defective NOTE: In this error condition, the toner supply is controlled using pixel count and Vsp/Vsg.
Description: TD sensor adjustment error 2
During the TD sensor auto adjustment, the TD sensor output voltage (Vt) does not come in the target range (2.5 ± 0.1V) within 20 seconds.
Causes: • TD sensor defective • Poor connection between the TD sensor and the I/O board. • I/O board defective NOTE: In this error condition, the toner supply is controlled using pixel count and Vsp/Vsg.
Description: ID sensor error 1
One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern. 1) Vsp ≥ 2.5V 2) Vsp = 0V
Causes: • ID sensor defective • ID sensor connector defective • Poor ID sensor connector connection • I/O board (IOB) defective • Charge or development power pack defective • Dirty ID sensor • Defect at ID sensor pattern writing area of the drum
Description: ID sensor error 2
One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern. 1) Vsg< 2.5V 2) Vsg = 0V 3) The ID sensor output voltage is 5.0V and the PWM signal input to the ID sensor is 0 when checking the ID sensor pattern
Causes: • ID sensor defective • ID sensor connector defective • Poor ID sensor connector connection • I/O board (IOB) defective • Charge or development power pack defective • Dirty ID sensor • Defect at the ID sensor pattern writing area of the drum
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.