Các lỗi thường gặp

Code :
  • Code: SC390
  • Description: CRC error
    Electrical noise causes sent data and received data to differ. A CRC check can detect this error.
  • Causes: • Defective connection board • Defective or disconnected interface cable
  • Code: SC391
  • Description: Image storage address error
    The SBICU receives an image data output request signal for data that is not stored in memory.
  • Causes: • SBICU defective
  • Code: SC400
  • Description: Transfer roller leak error
    A transfer roller current leak signal is detected.
  • Causes: • Transfer P.P. defective • Poor connection between the transfer current terminal and the transfer P.P.
  • Code: SC401
  • Description: Transfer roller open error
    The transfer roller current feedback signal is not detected
  • Causes: • Transfer P.P. defective • Poor connection between the transfer current terminal and the transfer P.P.
  • Code: SC430
  • Description: Quenching lamp error
    When finishing the process control initial setting, the drum potential which is detected by the drum potential sensor is out of the normal range
  • Causes: • Quenching lamp defective • Poor connection between quenching lamp and charge power pack
  • Code: SC440
  • Description: Main motor lock
    The main motor lock signal remains low for 2 seconds while the main motor is on.
  • Causes: • Too much load on the drive mechanism • Main motor defective
  • Code: SC441
  • Description: Development motor lock
    The development motor lock signal remains low for 2 seconds while the development motor is on.
  • Causes: • Too much load on the drive mechanism • Development motor defective
  • Code: SC493
  • Description: Exhaust fan motor lock
    The exhaust fan motor lock signal remains high for 5 seconds while the exhaust fan motor is on.
  • Causes: • Exhaust fan motor defective • Too much load on the fan