Description: ID sensor error 3
For 2 s during the ID sensor pattern check, the ID sensor pattern edge voltage is not 2.5V or the pattern edge is not detected within 800 ms.
Causes: • ID sensor defective
• ID sensor harness disconnected
• ID sensor connector defective
• IOB defective
• ID sensor pattern not written correctly
• Incorrect image density
• Charge power pack defective
• ID sensor dirty
Code: 353
Description: ID sensor error 4
One of the following ID sensor output voltages is detected at ID sensor initialization. . Vsg < 4.0V when the maximum PWM input (255) is applied to the ID sensor. . Vsg . 4.0V when the minimum PWM input (0) is applied to the ID sensor.
Causes: • ID sensor defective
• ID sensor harness disconnected
• ID sensor connector defective
• IOB defective
• ID sensor pattern not written correctly
• Incorrect image density
• Charge power pack defective
• ID sensor dirty
Code: 354
Description: ID sensor error 5
Vsg falls out of the adjustment target (4.0 ± 0.2V) during Vsg checking
Causes: • ID sensor defective
• ID sensor harness disconnected
• ID sensor connector defective
• IOB defective
• ID sensor pattern not written correctly
• Incorrect image density
• Charge power pack defective
• ID sensor dirty
Code: 355
Description: ID sensor error 6
The Vp value, which measures the reflectivity of the ID sensor pattern, was not in the range of –70V to –400V.
Description: Transfer output abnormal
When the transfer is output, the feedback voltage remains higher than 4V for 60 ms.
Causes: • Transfer power pack defective
• Transfer current terminal, transfer power pack disconnected, damaged connector
Code: 402
Description: Transfer output abnormal release detection
When the transfer is output, there is hardly any feedback voltage within 60 ms even with application of 24% PWM.
Causes: • Transfer power pack defective
• Transfer unit harness disconnected
• Transfer connector loose, defective
Code: 430
Description: Quenching lamp error
At the completion of auto process control initialization, the potential of the drum surface detected by the potential sensor is more than –400V, the prescribed value.