Description: Fusing temperature warming-up error
The fusing temperature does not reach the fusing standby temperature within 5 minutes after the main power switch is turned on.
Causes: • Fusing thermistor defective or out of position • Fusing lamp open • Fusing thermofuse open • BICU defective • Power supply board defective • Poor fusing unit connection
Description: Fusing overheat error 2
The fusing lamp stays on at full power for 45 seconds while in the stand-by condition after warming-up is completed.
Description: Fusing ready temperature malfunction
• A change in the fusing temperature by 20°C or more compared with the temperature of 1 second ago occurs 2 times consecutively. • A change in the fusing temperature by 20°C or more compared with the temperature of 1 second ago occurs 3 times consecutively for 1 minute.
Causes: • Poor connection on the thermistor • Poor connection on the fusing unit connector
Description: Zero cross signal malfunction
• When the main switch is on, the frequency measured by the number of zero cross signals for 500 ms is larger than 66Hz or smaller than 45Hz. • It is measured 3 times consecutively for 500 ms that the interval between a zero cross signal and the next one is 7.5 ms or shorter.
Causes: • Power supply unit defective • Noise on the ac power line
Description: Toner collection motor error
The toner collection motor sensor output does not change for 3 seconds while the toner collection motor is on.
Causes: • Toner collection motor defective • Too much load on the drive mechanism • Poor toner collection motor connector connection • IOB defective • Toner collection motor sensor defective
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.