Description: TD sensor initial setting error
TD sensor output voltage falls out of the adjustment range (2.0 ±<> 0.2 V) after the TD sensor initial setting has been finished.
Causes: • Someone forgot to remove the toner seal of the PCU • ID sensor defective • TD sensor abnormal • Drum does not turn • Development roller does not turn • Poor connection of the PCU
Description: Transfer roller leak error 1
A transfer roller current leak signal is detected. The current feedback signal for the transfer roller is not detected.
Causes: • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
Description: Transfer roller leak error 2
A transfer roller current leak signal is detected. The current feedback signal for the transfer roller is not detected.