Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio 3030 — Trang 3/17

Code: 302

Description: Charge roller error
A charge roller current leak signal is detected.
Causes: • Charge high voltage supply board defective • Connection at PCU loose, disconnected, or damaged

Code: 320

Description: Polygon motor error
• The XSCRDY signal did not activate (go LOW) within 10 sec. after the polygon motor turned on. • The XSCRDY signal did not deactivate (go HIGH) within 3 sec. after the polygon motor turned off. • The polygon motor continued to rotate for the prescribed number of rotations for 200 ms after the XSCRDY signal went HIGH (deactivated). • After the polygon motor turned on, or after the machine detected that the prescribed number of rotations had changed, the XSCRDY signal did not go LOW (active).
Causes: • Polygon motor I/F harness loose, disconnected, or defective • Polygon motor defective • Polygon motor driver defective • SBCU board defective

Code: 322

Description: Laser synchronization error
The main scan synchronization detector board cannot detect the laser synchronization signal for more than 10 consecutive 50 ms intervals.
Causes: • Poor connection between the laser synchronization detector board and the SBCU board • Laser synchronization detector board out of position • Laser synchronization detector board defective • SBCU board defective • LD unit defective

Code: 323

Description: LD drive current over
• The LD drive current exceeded 100 mA. • The XLDERR of the LD board was detected LOW twice within 100 ms. • Initialization of the PMACA failed.
Causes: • LD unit defective (not enough power, due to aging) • Poor connection between the LD unit and the SBCU board • SBCU board defective

Code: 350

Description: ID sensor calibration - Error 1
One of the following conditions occurred when the ID sensor pattern was calibrated during printing: • Vsp > 2.5V • Vsg < 2.5V • Vsp = 0V • Vsg = 0V
Causes: • ID sensor defective or dirty • ID sensor harness disconnected or connector is damaged • SBCU defective • Scanning system or image creation system malfunction • High voltage power supply board (power pack) defective

Code: 351

Description: ID sensor calibration - Error 2
The following conditions occurred simultaneously when the ID sensor pattern was calibrated during printing: • Vsg = 5V • PWM = 0 (LED current drop)
Causes: • ID sensor dirty or defective • ID sensor harness disconnected, or connector damaged • SBCU board defective • High voltage power supply board (power pack) defective

Code: 352

Description: ID sensor calibration - Error 3
During printing the 2.5V value for edge detection of the ID sensor pattern could not be detected after 800 ms.
Causes: • ID sensor dirty or defective • ID sensor harness disconnected, or connector damaged • SBCU defective • High voltage power supply board (power pack) defective

Code: 353

Description: ID sensor adjustment Error 1
Error occurred during automatic adjustment of Vsg: • Vsg output did not attain 4V, even with PWM = 255 (maximum current for LED) • Vsg output was greater than 4V, even with PWM=0 (no current for the LED)
Causes: • ID sensor dirty or defective • ID sensor harness disconnected, or connector damaged • SBCU defective • High voltage power supply board (power pack) defective • Scanning system or image creation system malfunction
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie