Các lỗi thường gặp

Code :
  • Code: 201
  • Description: Polygon motor error
    • The polygon motor starts operating or changes its speed. The lock signal is not detected within 5 seconds. • The polygon motor stops operating. The lock signal is still detected for 3 seconds. • The polygon motor is operating. The lock signal remains undetected for 0.5 seconds.
  • Causes: • Defective polygon motor • Defective harness
  • Code: 220
  • Description: 1st beam synchronization error
    A polygon motor lock is detected; the LD door is closed; and the LD remains on. The LD error (1st beam synchronization error) continues for 0.5 seconds.
  • Causes: • Disconnected synchronization detector board • Defective LD unit • Defective BICU
  • Code: 221
  • Description: 2nd beam synchronization error
    A polygon motor lock is detected; the LD door is closed; and the LD remains on. The LD error (2nd beam synchronization error) continues for 0.5 seconds.
  • Causes: • Disconnected synchronization detector board • Defective LD unit • Defective BICU
  • Code: 230
  • Description: FGATE on error
    A transfer belt mark is detected. No FGATE on signal is detected within 1 second.
  • Causes: • Defective BICU
  • Code: 231
  • Description: FGATE off error
    An FGATE assert signal is detected. The FGATE negate signal is not detected within 30 seconds.
  • Causes: • Defective BICU
  • Code: 241
  • Description: LD error
    An LD error continues for 0.5 seconds. (After an LD error is detected, an LD error release is written to the GAVD chip during monitoring.)
  • Causes: • Defective LD unit
  • Code: 280
  • Description: Image transfer belt mark detection error
    • An imaging process starts. No belt mark for the first color is detected within 5 seconds. • A color imaging process starts. A belt mark other than the one for the first color is not detected within 8 seconds after a former belt mark has been detected.
  • Causes: • Defective BICU • Poor electrical connection between sensor and BICU
  • Code: 282
  • Description: GAVD communication error
    Data is transferred. The status register in the BICU does not get to the ready condition within 10 milliseconds.
  • Causes: • Defective BICU