Mã lỗi Ricoh Aficio 3260C — Trang 25/31

Code: SC760

Description: Finisher punch motor error
The punch HP sensor is not activated within the specified time after the punch motor turned on. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Punch HP sensor disconnected, defective • Punch motor disconnected, defective • Punch motor overload due to obstruction

Code: SC761

Description: Finisher folder plate motor error
The folder plate moves but is not detected at the home position within the specified time. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Folder plate HP sensor disconnected, defective • Folder plate motor disconnected, defective • Folder plate motor overloaded due to obstruction.

Code: SC762

Description: Finisher pressure plate motor error
Pressure plate motor operating but the plate is not detected at the home position within the specified time. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Pressure plate HP sensor disconnected, defective • Pressure plate motor disconnected, defective • Pressure plate motor overloaded due to obstruction

Code: SC763

Description: Punch movement motor error
Occurs during operation of the punch unit. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Motor harness disconnected, loose, defective • Motor defective

Code: SC764

Description: Paper position sensor slide motor error
Occurs during operation of the punch unit. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Motor harness disconnected, loose, defective • Motor defective

Code: SC765

Description: Folding unit bottom fence lift motor
The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Motor harness disconnected, loose, defective • Motor defective

Code: SC766

Description: Clamp roller retraction motor error
The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Motor harness disconnected, loose, defective • Motor defective

Code: SC767

Description: Stack junction gate motor error
Occurs during operation of the punch unit. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Motor harness disconnected, loose, defective • Motor overload • Motor defective